Car, MITSUBISHI, OUTLANDER (GF), 2018, GF7W, XTXXZL6, Auto Stop & Go (AS&G)

Speed control - Auto Stop & Go (AS&G) - 0

Identification

Identifier: 00 00

ECU origin: 04

Supplier number: 64

ECU ID: 00

Diagnostic version: 00

Hardware version number: 01 01

Software version: 01 12 01

Part number: 1640A001

Software number: 1640A00101

VIN no (original): --

Class: --

Model: --

Type: --

Model year: --

VIN no: --

Calibration ID: --

Calibration verification number (CVN): --

DTC

P0830: Clutch pedal position (CPP) switch "B" - circuit malfunction

Controls

Clear DTC

Data stream

Neutral switch: Off

Engine hood: Close

Clutch switch buttom: Off

Clutch switch upper: Off

Ignition switch: Off

Auto stop & go (AS&G) off switch: Off

Starter switch: Off

DC/DC OUT for powertrain (Input): Off

DC/DC OUT (Input): Off

Seat belt fasten status: Fastened

Starter lock circuit status: Lock

Electric oil pump active status: On

Brake lamp switch: SNA

Parking brake switch: On

Brake hold signal (H/W): On

Clutch status: SNA

Driver side door switch: Close

Engine status: Stall

Brake hold signal (CAN): Off

Idle stop enable (ASC ECU): Enable

Idle stop enable (T/M ECU): Enable

Idle stop enable (ENG ECU): Enable

Idle stop enable (A/C ECU): Enable

Engine ECU auto stop & go system failure: Off

Idle Stop enable (T/F ECU): Enable

Electric oil pump system failure: Off

ACC vehicle hold status: Off

ASC ECU AS & G system failure: Off

Idle stop enable (ACC): Enable

T/M ECU AS & G system failure: Off

Parking brake status: Release

Auto hold status: Off

Brake vacuum sensor: 11.9 kPa

Air temperature: 1.5 °C

Barometric pressure sensor: 99.4 kPa

Vehicle speed: 0 km/h

Accelerator pedal position: 0.0 %

Idle stop enable (Vehicle speed): Disable

DC/DC in (Output): Off

Starter relay for AS&G (Output): Off

DC/DC in for powertrain (Output): Off

Starter relay (Output): Off

Starter counter: 16776960 times

Brake hold request mode flag: Off

AS & G indicator (Output): Turn on

AS & G off indicator (Output): Turn off

Idle stop flag: Off

Idle stop disable timer: 21 sec

Acceleration sensor signal(+ decel,- accel): -10.24 m/s²

Brake booster pressure sensor signal (CAN): 53.8 kPa

Utility

Controls

Starter counter writing

Starter counter initialization