PKW, MITSUBISHI, OUTLANDER (GF), 2016, GF8W, XTMPL#, Air Conditioner

Klimaregelung - Air Conditioner - 0

Identifikation

Identifikator: 00 02

ECU origin: 04

Lieferantennummer: 65

Steuergerät ID: 00

Diagnoseversion: 02

Hardwareversion: 00 01

Softwareversion: 00 01 01

Ersatzteilnummer: 7820A744

Softwarenummer: FFFFFF

FIN (ursprünglich): JMBXTGF3WDZ003948

Class: TG

Modell: Outlander / GF

Typ: GF3W

Modelljahr: 2013

FIN: JMBXTGF3WDZ003948

Kalibrierung ID: --

CVN: --

Fehlercode

B10C0: Innenraum-Temperatursensor - Kurzschluss

U0184: Lost communication with audio module

Controls

Fehlercode löschen

Ist-Werte

Interior temperature sensor: 13.0 °C

Air thermo sensor: 15.0 °C

Drucksensor: 0.43 MPa

Fotosensor: 0.0 W/m2

Geber für Kühlmitteltemperatur: 33 °C

Geber für Außentemperatur: 16.5 °C

Generator use rate: 0 %

Motordrehzahl: 0 UpM

Fahrgeschwindigkeit: 0 km/h

Driver air mix flap potentiometer: 100 %

Passenger air mix flap potentiometer: 100 %

Air outlet c/o potentiometer: 0 %

In/out select damp potentiometer: 0 %

Front blower fan: 0 Schritte

Target front blower fan: 0 Schritte

Air outlet c/o potentiometer (target): Face

In/out select damp poten (target): Fresh

A/C compressor drive request: AUS

Air conditioning switch: AUS

Schalter Heckscheibenheizung: AUS

Kondensator-Gebläse: 0 %

Idle up request: AUS

PTC heater 1: AUS

PTC heater 2: AUS

PTC heater 3: AUS

PTC heater operation flag: AUS

A/T lockup open request: AUS

High pressure fail flag: AUS

Low pressure fail flag: AUS

Refrigerant leak (Low pressure): Normal

Refrigerant leak (level 20%): Normal

Driver seat setting temperature: 23.0 °C

Set temperature (Passenger side): 23.0 °C

Heated windshield test mode flag: EIN

ECO mode: Komfort

Auto stop & go (AS&G): Normal

Idle stop disable flag: AUS

Idle stop cancellation request: AUS

A/C compressor drive flag: AUS

Wiper operation flag: AUS

Ignition position information: EIN

Power source voltage: 12.0 V

IOD fuse eqipment flag: EIN

Glühkerze: AUS

PTC heater 1 use times: 0 Count

PTC heater 2 use times: 0 Count

PTC heater 3 use times: 0 Count

In/out air c/o poten drive time: 3366.75 sec

Air outlet c/o poten drive time: 1443 sec

Air mix flap potentiometer drive time: 128 min

System operation time: 492405 sec

Compressor use times: 637 Count

Rear defogger use times: 22 Count

High pressure drive time: 0 min

High pressure cut times: 0

Höchstdruck: 1.97 MPa

A/C use rate: 25820 sec

Compressor operation rate: 4125 sec

Recirculation use rate: 45 min

Maximum engine coolant temperature: 98 °C

Engine high speed time: 0 sec

A/C operation times: 87 Count

In/out air c/o operation times: 42 Count

Fan M2 driving time: 5335 sec

Fan high driving time: 4095 sec

Fan lo driving time: 210795 sec

Fan M1 driving time: 200525 sec

Stellgliedtest

Controls

Idle up request

In/out select damper

Air outlet c/o damper

Kondensator-Gebläse

Schalter für Klimaanlage

Rear defogger switch

A/T lockup open request

PTC heater

As air mix damper motor

Front blower fan

Driver air mix damper motor

Dienst­programme

Controls

Heated windscreen test mode

Heated windscreen test mode stop