Bil, MITSUBISHI, ASX , OUTLANDER , RVR (GA), 2015, GA2W, XTHJZLC1, Air Conditioner
Klima Anlæg - Air Conditioner - 0
Identifikation
Identificere : 00 00
ECU origin: 04
Supplier number: 65
ECU ID: 00
Diagnose version: 00
Hardware version nummer: 00 01
Softwareversion: 00 15 10
Dele nummer: 7820A514
Software nummer:
VIN no (original): JA4AS3AW2CU016744
Class: S3
Model: Ikke defineret
Type: Ikke tilladt
Model year: 2012
Stel nr.: JA4AS3AW2CU016744
Calibration ID: --
Calibration verification number (CVN): --
Fejlkoder
U0163: Ingen kommunikation med navigationsstyremodul
Controls
Clear DTC
Levende Data
Interior temperature sensor: 13.0 °C
Air thermo sensor: 20.5 °C
Pressure sensor: 0.43 MPa
Motor kølevæske temperatur føler: 215 °C
Ambient temperature sensor: 16.5 °C
Generator use rate: 13 %
Motor Hastighed: 1056 Omdr.
Køretøjs hastighed : 1 km/h
Air mix potentiometer: 65410 %
Air outlet c/o potentiometer: 215 %
In/out select damp potentiometer: 88 %
Front blower fan: 0 steps
Target front blower fan: 0 steps
Air outlet c/o potentiometer (target): DEF/FOOT 3
In/out select damp poten (target):
A/C compressor drive request: Tænd
Air conditioning switch: Sluk
Bagrudeafdugningskontakt: Tænd
Condenser fan: 24 %
Idle up request: Low (Hot)
A/T lockup open request: Tænd
A/C setting temperature: -13.5 °C
A/C pressure protection control: Normal
Temp. set dial position:
A/C panel type: Type 0
Fan set dial position: Fejl
Air outlet c/o set dial position: Foot
Fan set dial operation flag: Tænd
Temp. set dial operation flag: Sluk
Defogger flag: Tænd
A/C switch operation flag: Tænd
In/out air c/o switch operation flag: Tænd
Rear defogger switch operation flag: Sluk
Rear defogger switch lamp: Tænd
A/C switch lamp: Tænd
In/out air c/o switch lamp: Tænd
A/C compressor drive flag: Sluk
Wiper operation flag: Sluk
Ignition position information: Tænd
Power source voltage: 0.1 V
IOD fuse eqipment flag: Tænd
In/out air c/o poten drive time: 168 sek
Air outlet c/o poten drive time: 15 sek
Air mix flap potentiometer drive time: 64 min
Hot state time (interior temperature): 583 min
Cold state time (interior temperature): 66 min
System operation time: 492405 sek
Hot state time (ambient temperature): 7000 min
Cold state time (ambient temperature): 255 min
Compressor use times: 637 Count
Rear defogger use times: 17 Count
High pressure drive time: 120 min
High pressure cut times: 255 Count
Maximum pressure: 1.97 MPa
A/C use rate: 413140 sek
Compressor operation rate: 4125 sek
Eco operation rate: 65 sek
Recirculation use rate: 410 min
Face mode use rate: 47 min
B/L mode use rate: 14 min
Maximum ambient temperature: -39.87 °C
Foot mode use rate: 10 min
D/F mode use rate: 15 min
Def mode use rate: 83 min
Minimum ambient temperature: -39.32 °C
Maximum engine coolant temperature: 215 °C
Engine high speed time: 585 sek
Maximum engine speed: 2783 Omdr.
Fan 5-6 step use rate: 60 sek
Fan 7-8 step use rate: 45 sek
Temp 1-7 step use rate: 10 min
Temp 8-10 step use rate: 0 min
Temp 11-13 step use rate: 40 min
Temp 17-19 step use rate: 55 min
Temp 20-22 step use rate: 30 min
Temp 23-29 step use rate: 30 min
A/C operation times: 87 Count
Fan off use rate: 65 sek
In/out air c/o operation times: 42 Count
Mode dial operation times: 10 Count
Blower dial operation times: 13 Count
Temp. set dial operation times: 1 Count
Fan 1-2 step use rate: 30 sek
Fan 3-4 step use rate: 55 sek
Fan M2 driving time: 330 sek
Fan high driving time: 210 sek
Fan lo driving time: 10 sek
Fan M1 driving time: 420 sek
Udgangs test
Controls
Idle up request
In/out select damper
Air outlet c/o damper
Condenser fan
A/C switch
Rear defogger switch
A/T lockup open request
Air mix damper motor
Front blower fan