Car, MITSUBISHI, GALANT , EVO (CY, Z), 2009, DBA-CY4A, STMHZ1, AFS, ACL, Leveling

Headlamp leveling - AFS/ACL/Leveling - 0

Identification

Identifier: 00 10

ECU origin: 04

Supplier number: 64

ECU ID: 00

Diagnostic version: 10

Hardware version number: 01 02

Software version: 02 01 13

Part number: 8634A049

Software number: 8634A04904

VIN no (original): JMBXJGA7WHZ400200

Class: JG

Model: Not defined

Type: Not allowed

Model year: 2017

VIN no: JMBXJGA7WHZ400200

Calibration ID: --

Calibration verification number (CVN): --

DTC

B2358: AFS OFF switch - circuit low voltage

Controls

Clear DTC

Data stream

AFS off switch: On

Power supply: 18.7 V

Rear height sensor initial position: -309.82 V

Height sensor initialization state: Completed

Height sensor power supply value: -309.80 V

A/L: Front HS signal: -117.47 V

Rear height sensor signal: -222.38 V

Front height sensor initial position: -309.82 V

A/L: H/L leveling system: Type 1

A/L: H/L leveling type: Not present

AFS/ACL type (CAN input): SNA

AFS off switch (CAN output): On

AFS/ACL indicator (CAN output): Off

A/L: Fail indicator (CAN output): Off

A/L: HS power fail flag: Off

A/L: Front HS signal fail flag: Off

A/L: Rear HS signal fail flag: Off

A/L: Actuator output fail flag: Off

AFS/ACL: Vehicle speed (CAN input): 0 km/h

AFS/ACL: SAS (CAN input): -26624.0 °

AFS/ACL: Turn SW LH (CAN input): Off

AFS/ACL: Turn SW RH (CAN input): Off

AFS/ACL: Bending lamp LH (CAN out): Off

AFS/ACL: Bending lamp RH (CAN out): On

Head lamp LO (CAN input): Off

Headlamp switch position (CAN input):

Head lamp HI (CAN input): Off

Reverse gear(CAN input): Off

A/L: Head lamp switch (Dimmer): Off

Parking brake switch (CAN input): Off

AFS/ACL: SAS status (CAN input): Normal

A/L actuator line voltage: 25.5 V

A/L actuator output voltage: 21.5 V

A/L: Hazard lamp SW (CAN input): On

A/L indicating voltage ratio: 2.2 %

Actuators test

Controls

Simulated speed input

Leveling actuator

Bending lamp LH

Bending lamp RH

Utility

Controls

HS initial position Clear

HS initial position Learning