PKW, MERCEDES, EQB 243, 243.608 EQB 300 4MATIC, Klimatisierungsautomatik (AAC)

Klimaregelung - Klimatisierungsautomatik (AAC) - 0

Identifikation

Diagnoseversion: 00 10 09

Boot software number: 33.1.2

Hardware-Version: 0.0.0

Softwareversion: 33.1.2

Software version 1: --

Software version 2: --

Lieferant: --

Hardware-Teilenummer:

Software part number (customer): 0104482140

Software part number (code): --

Software part number (data): --

Seriennummer: --

FIN:

VIN stored:

Fehlercode

U011100: Communication with battery control unit - malfunction

Controls

Fehlercode löschen

Ist-Werte

Causes of refrigerant compressor shutoff: Klimakompressor eingeschaltet

B12 (Kältemittel-Drucksensor): 141.5 Bar

Geber für Verdampfertemperatur: 376.0 °C

Outside air temperature sensor: 19.0 °C

Außenlufttemperatur : 12 °C

Interior temperature sensor with integrated fan: 53.0 °C

Interior temperature sensor with integrated fan: Stationär

Kühlmitteltemperatur: 73.0 °C

Motordrehzahl: 702 UpM

Batteriespannung: 12.0 V

Blower regulator supply voltage: 12.0 V

Blower regulator current consumption: 1.01 A

Blower regulator temperature: 123.0 °C

Gebläsemotor-Spannung: 7.1 V

Pumpe für Kühlmittelumlauf: AUS

Permissible deviation between actual and specified temperatures: Nicht aktiv

Outside temperature is too high: Nicht aktiv

ECO start/stop function is deactivated: Nicht aktiv

There is a risk of sudden fogging of windshield and side windows: Nicht aktiv

Not initialized: Nicht aktiv

Function 'Defrost' is active: Nicht aktiv

Cooling in vehicle interior: Nicht aktiv

Diagnose: Nicht aktiv

Coding 'ECO start/stop function' is deactivated in AAC control and operating unit: Nicht aktiv

Data transfer error: Nicht aktiv

Temperature measured at component 'Evaporator' is too high: Nicht aktiv

AC compressor electromagnetic clutch: Offen

Electric refrigerant compressor status: ---

Electric refrigerant compressor: 13.83 V

High-voltage battery cooling system shutoff valve: Schließen

Fresh air/recirculated air flap actuator motor

Current flap adjustment range: 1432

Stored flap adjustment range: 1289

Actual position of actuator motor: -8585

Specified position of actuator motor: 10629

Current position of actuator motor: 5 %

Position of actuator motor specified by control unit: 100 %

Central air distribution actuator motor

Current flap adjustment range: 2408

Stored flap adjustment range: 84

Actual position of actuator motor: -9389

Specified position of actuator motor: -7881

Current position of actuator motor: 12 %

Position of actuator motor specified by control unit: 10 %

Right blend air flap actuator motor

Current flap adjustment range: 1159

Stored flap adjustment range: 1033

Actual position of actuator motor: 12679

Specified position of actuator motor: 8550

Current position of actuator motor: 5 %

Position of actuator motor specified by control unit: 53 %

Stellgliedtest

Controls

Gebläse

Elektrischer Kältemittelkompressor

Stellmotor für Frisch-/Umluftklappe

Central air distribution actuator motor

Right blend air flap actuator motor

Fan motor

High-voltage battery cooling system shutoff valve

Dienst­programme

Controls

Normalization of actuator motors

Teach in actuator motors

Breaking-in of refrigerant compressor

Entriegeln Heizung

Konfiguration

Controls

Configuration coding

OBD coding

Comfort coding

Workshop storage