PKW, MERCEDES, VITO, VIANO 639, 639.605, -2008 D, Parameterizable special module (PSM)

Multifunktions Steuergerät - Parameterizable special module (PSM) - 0

Identifikation

MB Hardwarenummer: 9064467821

Diagnoseversion: 2.3

Hardwarenummer: 07.30

Softwarenummer: 07.34

Lieferant: Borg

Diagnoseversion: 02 03

Fehlercode

9809: PSM functionality 'Central locking' - Right sliding door could not be unlocked

Controls

Fehlercode löschen

Ist-Werte

Klemme 30 (1): 38 V

Klemme 30 (2): 26 V

Analog inputs: input 07: 38 V

Analog inputs: input 08: 51 V

Analog inputs: input 09: 52 V

Analog inputs: input 10: 4 V

Digital inputs: input 01: Operated

Digital inputs: input 02: Not operated

Digital inputs: input 03: Operated

Digital inputs: input 04: Not operated

Digital inputs: input 05: Operated

Digital inputs: input 06: Not operated

Digital inputs: input 07: Operated

Digital inputs: input 08: Not operated

Digital inputs: input 09: Operated

Digital inputs: input 10: Not operated

Output current values: output 01 (coded as 'High side'): 2 A

Output current values: output 01 (coded as 'Low side'): 18 A

Output current values: output 02 (coded as 'High side'): 49 A

Output current values: output 02 (coded as 'Low side'): 21 A

Output current values: output 03: 1 A

Output current values: output 04: 23 A

Output current values: output 05: 1 A

Output current values: output 06: 22 A

Output current values: output 07: 19 A

Output current values: output 08: 19 A

Output current values: output 09: 17 A

Output current values: output 10: 21 A

Output current values: output 11: 22 A

Output current values: output 12: 35 A

PWM outputs output 09 (Raw value): FF 00

PWM outputs output 10 (Raw value): 02 03

Digital outputs: output 01: Actuated

Digital outputs: output 02: Not actuated

Digital outputs: output 03: Actuated

Digital outputs: output 04: Not actuated

Digital outputs: output 05: Actuated

Digital outputs: output 06: Not actuated

Digital outputs: output 07: Actuated

Digital outputs: output 08: Not actuated

Digital outputs: output 11: Actuated

Digital outputs: output 12: Not actuated

Digital outputs: output 13: Actuated

Digital outputs: output 14: Not actuated

Digital outputs: output 15: Actuated

Digital outputs: output 16: Not actuated

Digital outputs: output 17: Actuated

Digital outputs: output 18: Not actuated

Digital outputs: output 19: Actuated

Digital outputs: output 20: Not actuated

Body CAN bus: fuel consumption (Resolution: 0.1 L): 3164930 L

Body CAN bus: operating hours counter: 240937.85 Stunden