PKW, MERCEDES, VITO, VIANO 639, 639.603, 2008-, Parameterizable special module (PSM)
Multifunktions Steuergerät - Parameterizable special module (PSM) - 0
Identifikation
MB Hardwarenummer: 9064467821
Diagnoseversion: 2.3
Hardwarenummer: 07.30
Softwarenummer: 07.34
Lieferant: Borg
Diagnoseversion: 02 03
Fehlercode
9809: PSM functionality 'Central locking' - Right sliding door could not be unlocked
Controls
Fehlercode löschen
Ist-Werte
Klemme 30 (1): 38 V
Klemme 30 (2): 26 V
Analog inputs: input 07: 38 V
Analog inputs: input 08: 51 V
Analog inputs: input 09: 52 V
Analog inputs: input 10: 4 V
Digital inputs: input 01: Operated
Digital inputs: input 02: Not operated
Digital inputs: input 03: Operated
Digital inputs: input 04: Not operated
Digital inputs: input 05: Operated
Digital inputs: input 06: Not operated
Digital inputs: input 07: Operated
Digital inputs: input 08: Not operated
Digital inputs: input 09: Operated
Digital inputs: input 10: Not operated
Output current values: output 01 (coded as 'High side'): 2 A
Output current values: output 01 (coded as 'Low side'): 18 A
Output current values: output 02 (coded as 'High side'): 49 A
Output current values: output 02 (coded as 'Low side'): 21 A
Output current values: output 03: 1 A
Output current values: output 04: 23 A
Output current values: output 05: 1 A
Output current values: output 06: 22 A
Output current values: output 07: 19 A
Output current values: output 08: 19 A
Output current values: output 09: 17 A
Output current values: output 10: 21 A
Output current values: output 11: 22 A
Output current values: output 12: 35 A
PWM outputs output 09 (Raw value): FF 00
PWM outputs output 10 (Raw value): 02 03
Digital outputs: output 01: Actuated
Digital outputs: output 02: Not actuated
Digital outputs: output 03: Actuated
Digital outputs: output 04: Not actuated
Digital outputs: output 05: Actuated
Digital outputs: output 06: Not actuated
Digital outputs: output 07: Actuated
Digital outputs: output 08: Not actuated
Digital outputs: output 11: Actuated
Digital outputs: output 12: Not actuated
Digital outputs: output 13: Actuated
Digital outputs: output 14: Not actuated
Digital outputs: output 15: Actuated
Digital outputs: output 16: Not actuated
Digital outputs: output 17: Actuated
Digital outputs: output 18: Not actuated
Digital outputs: output 19: Actuated
Digital outputs: output 20: Not actuated
Body CAN bus: fuel consumption (Resolution: 0.1 L): 3164930 L
Body CAN bus: operating hours counter: 240937.85 Stunden