Car, MERCEDES, GLB 247, 247.612 GLB 200 d, Automatic air conditioning (AAC)

Climate control - Automatic air conditioning (AAC) - 0

Identification

Diagnostic version: 00 10 09

Boot software number: 33.1.2

Hardware version: 0.0.0

Software version: 33.1.2

Software version 1: --

Software version 2: --

Supplier: --

Hardware part number:

Software part number (customer): 0104482140

Software part number (code): --

Software part number (data): --

Serial number: --

VIN no:

VIN stored:

DTC

U011100: Communication with battery control unit - malfunction

Controls

Clear DTC

Data stream

Causes of refrigerant compressor shutoff: A/C compressor switched on

Refrigerant pressure sensor: 141.5 bar

Evaporator temperature sensor: 376.0 °C

Outside air temperature sensor: 19.0 °C

Outside air temperature: 12 °C

Interior temperature sensor with integrated fan: 53.0 °C

Interior temperature sensor with integrated fan: Stationary

Coolant temperature: 73.0 °C

Engine speed: 702 rpm

Battery voltage: 12.0 V

Blower regulator supply voltage: 12.0 V

Blower regulator current consumption: 1.01 A

Blower regulator temperature: 123.0 °C

Blower motor voltage: 7.1 V

Coolant circulation pump: Off

Permissible deviation between actual and specified temperatures: Not active

Outside temperature is too high: Not active

ECO start/stop function is deactivated: Not active

There is a risk of sudden fogging of windshield and side windows: Not active

Not initialized: Not active

Function 'Defrost' is active: Not active

Cooling in vehicle interior: Not active

Diagnosis: Not active

Coding 'ECO start/stop function' is deactivated in AAC control and operating unit: Not active

Data transfer error: Not active

Temperature measured at component 'Evaporator' is too high: Not active

A/C compressor electromagnetic clutch: Open

Electric refrigerant compressor status: ---

Electric refrigerant compressor: 13.83 V

High-voltage battery cooling system shutoff valve: Close

Fresh air/recirculated air flap actuator motor

Current flap adjustment range: 1432

Stored flap adjustment range: 1289

Actual position of actuator motor: -8585

Specified position of actuator motor: 10629

Current position of actuator motor: 5 %

Position of actuator motor specified by control unit: 100 %

Central air distribution actuator motor

Current flap adjustment range: 2408

Stored flap adjustment range: 84

Actual position of actuator motor: -9389

Specified position of actuator motor: -7881

Current position of actuator motor: 12 %

Position of actuator motor specified by control unit: 10 %

Right blend air flap actuator motor

Current flap adjustment range: 1159

Stored flap adjustment range: 1033

Actual position of actuator motor: 12679

Specified position of actuator motor: 8550

Current position of actuator motor: 5 %

Position of actuator motor specified by control unit: 53 %

Actuators test

Controls

Blower

Electric refrigerant compressor

Fresh air and recirculated air flap actuator motor

Central air distribution actuator motor

Right blend air flap actuator motor

Fan motor

High-voltage battery cooling system shutoff valve

Utility

Controls

Normalization of actuator motors

Teach in actuator motors

Breaking-in of refrigerant compressor

Heater unlock

Configuration

Controls

Configuration coding

OBD coding

Comfort coding

Workshop storage