Bil, MERCEDES, VITO, METRIS 447, 447.813 V200, 220, 250 d 4MATIC, Marco Polo 4MATIC, V200, 220, 250 d, Marco Polo, V250, Automatic air conditioning (AAC)

Klima Anlæg - Automatic air conditioning (AAC) - 0

Identifikation

Diagnose version: 00 10 0E

Boot software number: 33.1.2

Hardwareversion: 8.2.0

Softwareversion: 8.2.0

Software version 1: --

Software version 2: --

Supplier: Hella

Hardware vare nummer: 2048203226

Software part number (customer): 0104482140

Software part number (code): --

Software part number (data): --

Serie nummer: 01 00 00 00 00 00 00 00 00 00 00 00

Stel nr.: WDC1660041Z000815

VIN stored:

Fejlkoder

Controls

Clear DTC

Levende Data

Refrigerant pressure sensor: 18 bar

Kølemiddeltemperatur: 61 °C

Outside temperature: 2 °C

Motor Hastighed: 837 Omdr.

Køretøjs hastighed : 7 km/h

Power supply voltage (CAN): 15.2 V

Evaporator temperature sensor: 45 °C

Interior air temperature sensor: 400 °C

Coolant circulation pump: Sluk

A/C compressor regulating valve: 4 %

A/C compressor regulating valve: 33.5 A

AC compressor electromagnetic clutch: Sluk

Shutoff of refrigerant compressor: Refrigerant compressor switched on

Blæsermotor: 17.0 V

Governor supply voltage: 9.0 V

Governor power consumption: 11.1 A

Current limiting: Nej

Blæsermotor: -50 °C

Rear windshield heater: Sluk

Permissible deviation between actual and specified temperatures: Ikke aktiv

Outside temperature is too high: Nej

ECO start/stop function is deactivated: Ikke aktiv

There is a risk of sudden fogging of windshield and side windows: Ikke aktiv

Initialization: Ikke aktiv

Function 'Defrost' is active: Nej

Cooling in vehicle interior: Ikke aktiv

Coding 'ECO start/stop function' is deactivated in AAC control and operating unit: Ikke aktiv

Data transfer error: Ikke aktiv

Diagnosis: Ikke aktiv

Temperature measured at component 'Evaporator' is too high: Ikke aktiv

Compressor status: Udefineret

Operation of refrigerant compressor is disabled: Nej

Abort reason: No fault

Current flap adjustment range: 30360

Stored flap adjustment range: 48163

Actual position of actuator motor: -9097

Specified position of actuator motor: 8820

Current position of actuator motor: 100 %

Position of actuator motor specified by control unit: 9 %

Overvoltage/Undervoltage: Ikke aktiv

Excessive temperature: Ikke aktiv

Udgangs test

Controls

Refrigerant compressor

Front blower

Left blend air flap actuator motor

Air distribution flap actuator motor