PKW, MERCEDES, VITO, METRIS 447, 447.703, Klimatisierungsautomatik (AAC)

Klimaregelung - Klimatisierungsautomatik (AAC) - 0

Identifikation

Diagnoseversion: 00 10 0E

Boot software number: 33.1.2

Hardware-Version: 8.2.0

Softwareversion: 8.2.0

Software version 1: --

Software version 2: --

Lieferant: Hella

Hardware-Teilenummer: 2048203226

Software part number (customer): 0104482140

Software part number (code): --

Software part number (data): --

Seriennummer: 01 00 00 00 00 00 00 00 00 00 00 00

FIN: WDC1660041Z000815

VIN stored:

Fehlercode

Controls

Fehlercode löschen

Ist-Werte

B12 (Kältemittel-Drucksensor): 18 Bar

Kühlmitteltemperatur: 61 °C

Outside temperature: 2 °C

Motordrehzahl: 837 UpM

Fahrgeschwindigkeit: 7 km/h

Power supply voltage (CAN): 15.2 V

Geber für Verdampfertemperatur: 45 °C

Interior air temperature sensor: 400 °C

Pumpe für Kühlmittelumlauf: AUS

A/C compressor regulating valve: 4 %

A/C compressor regulating valve: 33.5 A

AC compressor electromagnetic clutch: AUS

Shutoff of refrigerant compressor: Kältemittelverdichter eingeschaltet

Gebläsemotor: 17.0 V

Governor supply voltage: 9.0 V

Governor power consumption: 11.1 A

Current limiting: Nein

Gebläsemotor: -50 °C

Rear windshield heater: AUS

Permissible deviation between actual and specified temperatures: Nicht aktiv

Outside temperature is too high: Nein

ECO start/stop function is deactivated: Nicht aktiv

There is a risk of sudden fogging of windshield and side windows: Nicht aktiv

Initialisierung: Nicht aktiv

Function 'Defrost' is active: Nein

Cooling in vehicle interior: Nicht aktiv

Coding 'ECO start/stop function' is deactivated in AAC control and operating unit: Nicht aktiv

Data transfer error: Nicht aktiv

Diagnose: Nicht aktiv

Temperature measured at component 'Evaporator' is too high: Nicht aktiv

Compressor status: Unbestimmt

Operation of refrigerant compressor is disabled: Nein

Abort reason: No fault

Current flap adjustment range: 30360

Stored flap adjustment range: 48163

Actual position of actuator motor: -9097

Specified position of actuator motor: 8820

Current position of actuator motor: 100 %

Position of actuator motor specified by control unit: 9 %

Überspannung/Unterspannung: Nicht aktiv

Übertemperatur: Nicht aktiv

Stellgliedtest

Controls

Kältemittelverdichter

Front blower

Left blend air flap actuator motor

Antriebsmotor Luftverteilerklappe