PKW, MERCEDES, VITO, METRIS 447, 447.603, Powertrain control unit (PTCU)

Motor - Powertrain control unit (PTCU) - 0

Identifikation

Diagnoseversion: 02 B1 81

Boot software number: 11.39.5

Hardware-Version: 12.27.0

Softwareversion: 12.48.5

Software version 1: 14.45.3

Software version 2: 15.5.20

Lieferant: Delphi

Hardware-Teilenummer: 0009016402

Software part number (customer): 0009041700

Software part number (code): 0009020929

Software part number (data): 0009039805

Seriennummer: 30 30 38 39 31 31 35 32 36 34 33 35

Fehlercode

U015587: Communication with instrument cluster has a malfunction. Message is missing

Controls

Fehlercode löschen

Ist-Werte

Battery voltage raw value: -- V

Batteriespannung: 4.5 V

Geber für Fahrpedal 1: 0.00 %

Geber für Fahrpedal 2: 0.00 %

Gaspedalposition: 7.25 %

Unterdruckpumpe: -- V

Brake vacuum: 0.0 V

Brake vacuum: 0.0 hPa

Brake vacuum: No AD conversion error

Bremsmoment: 12285.00 N·m

Fahrgeschwindigkeit: -- km/h

Cooling temperature sensor powertrain electronics (low temperature circuit 1): -- °C

Cooling temperature sensor HV battery (low temperature circuit 2): -- °C

Cooling level sensor (low temperature circuit 1): In Ordnung

Kickdown: Nein

Stromkreis 87: -- V

Stromkreis 15: EIN

Wake up status: --

Gearshift lever neutral position: --

Powertrain system mode: --

Stromkreis 50: AUS

Gearshift lever position: --

High-voltage battery charge level: 0.00 %

High voltage battery usable capacity: 0.00 As

High-voltage battery current value: 0.0 A

DC/DC converter 12V on-board electrical system voltage: 15.00 V

DC/DC converter high-voltage on-board electrical system voltage: 0.00 V

DC/DC converter control unit: Standby

High-voltage battery voltage: 0.00 V

Stromkreis 87: AUS

Kühlgebläse: 0.00 %

Cooling pump 3 (low temperature circuit 1): 0.00 %

Cooling pump 4 (low temperature circuit 2): -- %

Cooling switch valve chiller (low temperature circuit 2): --

Stellgliedtest

Controls

Stellantrieb Bypass

Circuit 87 power supply

Cooling HV-PTC

Cooling expansion valve chiller (low temperature circuit 2)

Cooling fan control

Cooling lower cooler louver diagnostic

Cooling pump 1 (high temperature circuit)

Cooling pump 2 (high temperature circuit)

Cooling pump 3 (low temperature circuit 1)

Cooling pump 4 (low temperature circuit 2)

Cooling rotary slide valve (high temperature circuit)

Cooling rotary slide valve (low temperature circuit 1)

Cooling rotary slide valve (low temperature circuit 2)

Cooling switch valve chiller (low temperature circuit 2)

Cooling upper cooler louver diagnostic

Electric vacuum pump test

Low or high state of charge (SOC)

Ladezustand

Zero current mode