Car, MERCEDES, B 245, 245.232 B 170, 2005-, Automatic air conditioning (AAC)
Climate control - Automatic air conditioning (AAC) - 0
Identification
Production date: 06 10 11
Hardware number: 01.06
Software number: 10.06
Diagnostic version: 2.8
MB number for hardware: 16 95 45 19 08
Supplier: Not defined
Identifier: 02 08
VIN no: WDD2452071J177852
DTC
9001: Interrior air temperature sensor - circuit open or short
Controls
Clear DTC
Data stream
Power supply: 12 V
Engine speed: 0 rpm
Ambient temperature sensor: 55 °C
Interior air temperature sensor: 15 °C
Engine coolant temperature sensor: 33 °C
Evaporator temperature sensor: 26 °C
Rear blower electronic selector wheel: 3
Left sun sensor light intensity: 0 %
Right sun sensor light intensity: 0 %
Air quality sensor: 14.0 %
Multifunction sensor dewpoint temperature: 54 °C
Request to A/C compressor: 17 %
A/C compressor current consumption: 2048 mA
Defroster flap actuator motor position: 0 %
Target defroster flap actuator motor position: 0 %
Defroster flap actuator motor position: 0
Target defroster flap actuator motor position: 0
Stored defroster flap adjustment motor travel: 1299
Current defroster flap adjustment motor travel: 1299
Defroster flap normalizing of positioning motors: Performed
Defroster flap alignment of positioning motors: Not performed
Defroster flap mode: Normal
Defroster flap overvoltage/undervoltage: No
Defroster flap communication fault: No
Defroster flap excess temperature: No
Defroster flap electrical fault: No
Footwell flap motor position: 100 %
Target footwell flap positioning motor: 100 %
Footwell flap motor position: 1138
Target footwell flap positioning motor: 1138
Stored footwell flap adjustment motor travel: 1138
Current footwell flap adjustment motor travel: 1138
Footwell flap normalizing of positioning motors: Performed
Footwell flap alignment of positioning motors: Performed
Footwell flap mode: Normal
Footwell flap overvoltage/undervoltage: No
Footwell flap communication fault: No
Footwell flap excess temperature: No
Footwell flap electrical fault: No
Center outlet flap actuator motor position: 100 %
Target center outlet flap actuator motor position: 100 %
Center outlet flap actuator motor position: 1033
Target center outlet flap actuator motor position: 1033
Stored center outlet flap adjustment motor travel: 1033
Current center outlet flap adjustment motor travel: 1033
Center outlet flap normalizing of positioning motors: Performed
Center outlet flap alignment of positioning motors: Performed
Center outlet flap mode: Normal
Center outlet flap overvoltage/undervoltage: No
Center outlet flap communication fault: No
Center outlet flap excess temperature: No
Center outlet flap electrical fault: No
Recirculation air flap actuator motor position: 100 %
Target recirculation air flap actuator motor position: 100 %
Recirculation air flap actuator motor position: 1936
Target recirculation air flap actuator motor position: 1936
Stored recirculation air flap adjustment motor travel: 1936
Current recirculation air flap adjustment motor travel: 1936
Recirculation air flap normalizing of positioning motors: Performed
Recirculation air flap alignment of positioning motors: Performed
Recirculation air flap mode: Normal
Recirculation air flap overvoltage/undervoltage: No
Recirculation air flap communication fault: No
Recirculation air flap excess temperature: No
Recirculation air flap electrical fault: No
Left air mix flap motor position: 100 %
Target left air mix flap motor position: 100 %
Left air mix flap motor position: 1344
Target left air mix flap motor position: 1344
Stored left air mix flap adjustment motor travel: 1344
Current left air mix flap adjustment motor travel: 1344
Left air mix normalizing of positioning motors: Performed
Left air mix flap alignment of positioning motors: Performed
Left air mix flap mode: Normal
Left air mix flap overvoltage/undervoltage: No
Left air mix flap communication fault: No
Left air mix flap motor excess temperature: No
Left air mix flap motor electrical fault: No
Right air mix flap actuator motor position: 100 %
Target right air mix flap actuator motor position: 100 %
Right air mix flap actuator motor position: 1313
Target right air mix flap actuator motor position: 1313
Stored right air mix flap adjustment motor travel: 1313
Current right air mix flap adjustment motor travel: 1313
Right air mix normalizing of positioning motors: Performed
Right air mix flap alignment of positioning motors: Not performed
Right air mix flap mode: Normal
Right air mix flap overvoltage/undervoltage: No
Right air mix flap communication fault: No
Right air mix flap motor excess temperature: No
Right air mix flap motor electrical fault: No
Rear shutoff flap actuator motor position: 80 %
Target rear shutoff flap actuator motor position: 80 %
Rear shutoff flap actuator motor position: 1117
Target rear shutoff flap actuator motor position: 1117
Stored rear shutoff flap adjustment motor travel: 1397
Current rear shutoff flap adjustment motor travel: 1397
Rear shutoff flap normalizing of positioning motors: Performed
Rear shutoff flap alignment of positioning motors: Performed
Rear shutoff flap mode: Normal
Rear shutoff flap overvoltage/undervoltage: No
Rear shutoff flap communication fault: No
Rear shutoff flap excess temperature: No
Rear shutoff flap electrical fault: No
Temperature sensor: 25 °C
Blower motor current consumption: 0 A
Blower motor voltage: 0 V
Excessive temperature: No
Blower motor fault: No fault
Mode: Normal
Status: Stationary
In-car temperature sensor: -- °C
Actuators test
Controls
Defroster flap
Footwell flaps
Center outlet flap
Recirculated air flap
Left air mix flap motor
Right air mix flap motor
Rear shutoff flap
Blower motor
Electric suction fan
Illumination
Closing air recirculation flap (for cleaning)
Heating water circulation pump
Utility
Controls
Normalizing of positioning motors
Check of adjustment range of positioning motors
Teach in actuator motors
Breaking-in after replacement of refrigerant compressor
Configuration
Controls
Edit configuration