Bil, MERCEDES, Sprinter 907, 907.633, Automatic air conditioning (AAC)

Klima Anlæg - Automatic air conditioning (AAC) - 0

Identifikation

Diagnose version: 00 10 09

Boot software number: 33.1.2

Hardwareversion: 0.0.0

Softwareversion: 33.1.2

Software version 1: --

Software version 2: --

Supplier: --

Hardware vare nummer:

Software part number (customer): 0104482140

Software part number (code): --

Software part number (data): --

Serie nummer: --

Stel nr.:

VIN stored:

Fejlkoder

U011100: Communication with battery control unit - malfunction

Controls

Clear DTC

Levende Data

Causes of refrigerant compressor shutoff: A/C compressor switched on

Refrigerant pressure sensor: 141.5 bar

Evaporator temperature sensor: 376.0 °C

Outside air temperature sensor: 19.0 °C

Outside air temperature: 12 °C

Interior temperature sensor with integrated fan: 53.0 °C

Interior temperature sensor with integrated fan: Stationær

Kølemiddeltemperatur: 73.0 °C

Motor Hastighed: 702 Omdr.

Batteri spænding: 12.0 V

Blower regulator supply voltage: 12.0 V

Blower regulator current consumption: 1.01 A

Blower regulator temperature: 123.0 °C

Blæsermotor, spænding: 7.1 V

Coolant circulation pump: Sluk

Permissible deviation between actual and specified temperatures: Ikke aktiv

Outside temperature is too high: Ikke aktiv

ECO start/stop function is deactivated: Ikke aktiv

There is a risk of sudden fogging of windshield and side windows: Ikke aktiv

Not initialized: Ikke aktiv

Function 'Defrost' is active: Ikke aktiv

Cooling in vehicle interior: Ikke aktiv

Diagnosis: Ikke aktiv

Coding 'ECO start/stop function' is deactivated in AAC control and operating unit: Ikke aktiv

Data transfer error: Ikke aktiv

Temperature measured at component 'Evaporator' is too high: Ikke aktiv

AC compressor electromagnetic clutch: Åben

Electric refrigerant compressor status: ---

Electric refrigerant compressor: 13.83 V

High-voltage battery cooling system shutoff valve: Ctabe

Fresh air/recirculated air flap actuator motor

Current flap adjustment range: 1432

Stored flap adjustment range: 1289

Actual position of actuator motor: -8585

Specified position of actuator motor: 10629

Current position of actuator motor: 5 %

Position of actuator motor specified by control unit: 100 %

Central air distribution actuator motor

Current flap adjustment range: 2408

Stored flap adjustment range: 84

Actual position of actuator motor: -9389

Specified position of actuator motor: -7881

Current position of actuator motor: 12 %

Position of actuator motor specified by control unit: 10 %

Right blend air flap actuator motor

Current flap adjustment range: 1159

Stored flap adjustment range: 1033

Actual position of actuator motor: 12679

Specified position of actuator motor: 8550

Current position of actuator motor: 5 %

Position of actuator motor specified by control unit: 53 %

Udgangs test

Controls

Blower

Electric refrigerant compressor

Fresh air and recirculated air flap actuator motor

Central air distribution actuator motor

Right blend air flap actuator motor

Fan motor

High-voltage battery cooling system shutoff valve

Muligheder

Controls

Normalization of actuator motors

Teach in actuator motors

Breaking-in of refrigerant compressor

Heater unlock

Konfiguration

Controls

Configuration coding

OBD coding

Comfort coding

Workshop storage