Car, MERCEDES, Sprinter 906, 906.132, 2013-, Parameterizable special module (PSM)
Special multifunction module - Parameterizable special module (PSM) - 0
Identification
MB number for hardware: 9064467821
Diagnostic version: 3.5
Hardware number: 07.30
Software number: 07.34
Supplier: Borg
Diagnostic version: 03 05
DTC
9809: PSM functionality 'Central locking' - Right sliding door could not be unlocked
Controls
Clear DTC
Data stream
Voltage terminal 30.1: 2 V
Voltage terminal 30.2: 60 V
Analog inputs: input 07: 2 V
Analog inputs: input 08: 38 V
Analog inputs: input 09: 51 V
Analog inputs: input 10: 43 V
Digital inputs: input 01: Operated
Digital inputs: input 02: Not operated
Digital inputs: input 03: Operated
Digital inputs: input 04: Not operated
Digital inputs: input 05: Operated
Digital inputs: input 06: Not operated
Digital inputs: input 07: Operated
Digital inputs: input 08: Not operated
Digital inputs: input 09: Operated
Digital inputs: input 10: Not operated
Output current values: output 01 (coded as 'High side'): 34 A
Output current values: output 01 (coded as 'Low side'): 19 A
Output current values: output 02 (coded as 'High side'): 11 A
Output current values: output 02 (coded as 'Low side'): 19 A
Output current values: output 03: 37 A
Output current values: output 04: 5 A
Output current values: output 05: 39 A
Output current values: output 06: 35 A
Output current values: output 07: 30 A
Output current values: output 08: 21 A
Output current values: output 09: 18 A
Output current values: output 10: 52 A
Output current values: output 11: 48 A
Output current values: output 12: 18 A
PWM outputs output 09 (Raw value): FF 00
PWM outputs output 10 (Raw value): 00 FF
Digital outputs: output 01: Actuated
Digital outputs: output 02: Not actuated
Digital outputs: output 03: Actuated
Digital outputs: output 04: Not actuated
Digital outputs: output 05: Actuated
Digital outputs: output 06: Not actuated
Digital outputs: output 07: Actuated
Digital outputs: output 08: Not actuated
Digital outputs: output 11: Actuated
Digital outputs: output 12: Not actuated
Digital outputs: output 13: Actuated
Digital outputs: output 14: Not actuated
Digital outputs: output 15: Actuated
Digital outputs: output 16: Not actuated
Digital outputs: output 17: Actuated
Digital outputs: output 18: Not actuated
Digital outputs: output 19: Actuated
Digital outputs: output 20: Not actuated
Body CAN bus: fuel consumption (Resolution: 0.1 L): 49465 L
Body CAN bus: fuel consumption (Resolution: 0.001 L): 4011081.000 L
Body CAN bus: operating hours counter: 476805.75 H