Bil, MERCEDES, Sprinter 906, 906.131, 2013-, Selective catalytic reduction (SCR)
Motor - Selective catalytic reduction (SCR) - 0
Identifikation
Diagnose version: 00 17 21
Boot software number: 33.1.2
Hardwareversion: 8.2.0
Softwareversion: 8.2.0
Software version 1: --
Software version 2: --
Supplier: Bosch
Hardware vare nummer: 2048203226
Software part number (customer): 0104482140
Software part number (code): --
Software part number (data): --
Serie nummer: --
Stel nr.: WDC1660041Z000815
VIN stored: WD3PE8CCXF5952658
Fejlkoder
000100: Ignore fault code if it nevertheless occurs
20B811: Output for heating element of AdBlue delivery module - circuit short to battery
20BD13: Output for heating element 'AdBlue tank' electrical fault or circuit open
Controls
Clear DTC
Levende Data
Exhaust temperature upstream of SCR catalytic converter: -0 °C
Pressure in AdBlue delivery pump: 0 hPa
Status of AdBlue tank fill level sensor EMPTY: 0.0
Status of AdBlue tank fill level sensor RESERVE: 0.0
Status of AdBlue tank fill level sensor FULL: 8200.0
Heating of AdBlue tank module: 0 mA
Heater of AdBlue line: 0 mA
Heating of AdBlue delivery module: 0 mA
Temperature in AdBlue tank: 30 °C
Pressure in AdBlue delivery pump: 0 hPa
Fuel tank level: 31 L
Fuel tank level: 100.00 %
Temperature in AdBlue tank: -5302 mV
AdBlue fill level sensor 1 (raw value): 896 mV
AdBlue fill level sensor 2 (raw value): -6134 mV
AdBlue fill level sensor 3 (raw value): -6130 mV
Fill level of AdBlue tank: Tom
Engine start: A3
Heating of AdBlue pressure line: Actuated
Heating of AdBlue tank module: Actuated
Heating of AdBlue delivery module: Not actuated
System status of control unit SCR: Pressure reduction
AdBlue reversing valve: Switching of reversing valve in direction 'AdBlue metering valve'
Batteri spænding: 8.040 V
Køretøjets hastighed sensor: 0 km/h
Actual lambda value: 0
Ambient temperature sensor: 177 °C
Barometrisk tryk føler: 4498 hPa
Motor Hastighed: 500 Omdr.
Pressure in AdBlue delivery pump: -54.60 %
Fill quantity in AdBlue pressure line: 93 %
AdBlue metering valve: 100 %
Connector AdBlue metering valve: Tilsluttet
Warning lamp 'AdBlue': Sluk
Udgangs test
Controls
Heating of AdBlue tank module
Heating of AdBlue pressure line
Heating of AdBlue delivery module
AdBlue reversing valve
AdBlue delivery pump
AdBlue return
Muligheder
Controls
Display consumption
Resetting calculated fill level of AdBlue tank