PKW, MERCEDES, SMART 451, 451.400, Sprintshift control moduletpm (SSCM)
Transaxle - Sprintshift control moduletpm (SSCM) - 0
Identifikation
MB Hardwarenummer: 4515454132
Diagnoseversion: 0.5
Hardwarenummer: 13.06
Softwarenummer: 00.34
Lieferant: Nicht definiert
Diagnoseversion: 00 05
FIN (ursprünglich): WME4513321K234946
FIN: WME4513321K234946
Fehlercode
Controls
Fehlercode löschen
Ist-Werte
FIN (ursprünglich): WME4513321K234946
FIN: WME4513321K234946
Original VIN writing status: Interlocked
Seriennummer: 22 08 53 00 00 51
Batteriespannung: 12 V
Eingestellter Gang: Nullstellung
Status Kupplung: Offen
Clutch protection class 3: 34855
Actual clutch position: 61200 inch
Specified clutch position: 60720
Average clutch drag point: 25588 lnk
Maximum end stop clutch position: 410
Mileage of clutch: 70 km
Kupplung: 4715 W
Power loss of clutch: 2805
Power loss of clutch: 1180 W
Power loss of clutch: 187535
Clutch protection class: 25
Counter for clutch protection class 1: 37155
Counter for clutch protection class 2: 58181
Time in clutch protection class 3: 33427 min
Counter for clutch protection class 3: 39192
Raddrehzahlsensor vorn links: 19596 UpM
Raddrehzahlsensor vorne rechts: 28834 UpM
Fault selector drum movement: Fault while engaging gear
Raddrehzahlsensor hinten links: 4514 UpM
Raddrehzahlsensor hinten rechts: 10777 UpM
Fault transmission: Emergency running
Speed of driven axle: 0.00 km/h
Speed of non-driven axle: 0.00 km/h
Gear position (current): Nullstellung
Drehzahl Getriebeeingangswelle: 47890 UpM
Getriebeausgangsdrehzahl: 52376 UpM
Gear position (target): Gang 1
Motordrehzahl: 0 UpM
Selector lever raw value: 17
Selector lever: Nullstellung
Program selector switch: Not operated
Position of selector drum 1: 90.0000 °
Position of selector drum 2: 0.0000 °
Position of selector drum 1 (Down): 1.12 °
Position of selector drum 1 (Up): 230.12 °
Position of selector drum 2 (Down): 2.06 °
Position of selector drum 2 (Up): 235.00 °
Getriebetemperatur: 105 °C
Engine Temperature: 190 °C
Fault status selector drum movement 1: Wiring fault
Fault status selector drum movement 2: No reaction
Learning status selector drum movement 1: The actual value is not within the permissible range
Learning status selector drum movement 2: Internal time-out
Automated manual transmission relay: 34.57 V
Automated manual transmission relay (Output): 145.50 V
Status relay SEQ: EIN
Dienstprogramme
Controls
Kupplung anlernen
Open clutch
Close clutch
Funktionstest 1, 2 (Automatischer Test)
Funktionstest 3
Teach transmission
Switch on relay Transmission
Shift into individual gears
Energize transmission with specified value (Transmission motor 1)
Energize transmission with specified value (Transmission motor 2)