Bil, MERCEDES, SL 230, 230.479 SL 65 AMG, 2008-, Automatic air conditioning (AAC)

Klima Anlæg - Automatic air conditioning (AAC) - 0

Identifikation

MB number for hardware: 23 08 30 01 85

Diagnose version: 2.5

Hardware number: 04.03

Software nummer: 07.02

Supplier: VDO

Diagnose version: 45

Stel nr.: --

Fejlkoder

U2190: Ukendt fejlkode

P0690: Ukendt fejlkode

P0190: Ukendt fejlkode

Controls

Clear DTC

Levende Data

N22b1 (In-car temperature sensor): 1 °C

Interior temperature sensor with fan (OCP): 51 °C

Ambient temperature display temperature sensor: 17 °C

Evaporator temperature sensor: 51 °C

Motor kølevæske temperatur føler: 17 °C

A/C refrigerant pressure sensor: 23 bar

A/C refrigerant temperature sensor: 17 °C

A/C refrigerant compressor: 51 %

Fan capacity request by air conditioning: 17 %

Køretøjets hastighed sensor: 17 km/h

Motor Hastighed: 13107 Omdr.

Blower motor current consumption: 10 A

A32m1 (Blower motor): short circuit cut-off: Nej

A32m1 (Blower motor): maximum current limit: Nej

Blower regulator: 100%: Nej

Blower regulator control module overload of output: Nej

Blower regulator: excess temperature: Nej

Overvoltage: Ja

Output stage: Inaktiv

Terminal 58d: 119 %

A/C compressor drive request: Sluk

Feedback of AC compressor actuation: Sluk

Full throttle cut-off of AC compressor: Sluk

Emergency off circuit of AC compressor: Sluk

C-AAC sun sensor (4 in total) total light intensity: 26 %

Right front sun sensor light intensity: 42 %

Left front sun sensor light intensity: 26 %

Right rear sun sensor light intensity: 42 %

Left rear sun sensor light intensity: 26 %

Multifunction sensor CO value: 974

Multifunction sensor NOx value: 771

Humidity sensor: 60 %

Multifunction sensor dewpoint temperature: 20 °C

'Warm air' pushbutton (center vent): Sluk

'Cold air' pushbutton (center vent): Sluk

Rotary potentiometer for setting air quantity at center vent: 8 %

Rotary potentiometer for setting air quantity at left side vent: 26 %

Rotary potentiometer for setting air quantity at right side vent: 42 %

Request to heating water circulation pump: Sluk

Feedback from heating water circulation pump: Sluk

Request to fan motor of 'interior air' temperature sensor: Sluk

Feedback from fan motor of 'interior air' temperature sensor: Sluk

Request to rear window defroster: Sluk

Feedback from rear window defroster: Tænd

Target right center ventilation air flap motor position: 1456 steps

Right center ventilation air flap motor position: 1456 steps

Stored right center ventilation air flap adjustment motor travel: 2694 steps

Current right center ventilation air flap adjustment motor travel: 2707 steps

Lost communication between AAC pushbutton control module and right center ventilation air flap motor: Nej

Right center ventilation air flap motor electrical fault: Nej

Right center ventilation air flap motor mechanical fault: Nej

Right center ventilation air flap motor excess temperature: Nej

Right center ventilation air flap motor position motor alignment: OK

Target left center ventilation air flap motor position: 1578 steps

Left center ventilation air flap actuator motor position: 1578 steps

Stored left center ventilation air flap adjustment motor travel: 2719 steps

Current left center ventilation air flap adjustment motor travel: 2709 steps

Lost communication between AAC pushbutton control module and left center ventilation air flap motor: Nej

Left center ventilation air flap motor electrical fault: Nej

Left center ventilation air flap motor mechanical fault: Nej

Left center ventilation air flap motor excess temperature: Nej

Left center ventilation air flap motor position motor alignment: OK

Target diverter flap actuator motor position: 0 steps

Diverter flap actuator motor position: 0 steps

Stored diverter flap adjustment motor travel: 1753 steps

Current diverter flap adjustment motor travel: 1828 steps

Lost communication between AAC pushbutton control module and diverter flap motor: Nej

Diverter flap actuator electrical fault: Nej

Diverter flap motor mechanical fault: Nej

Diverter flap actuator excess temperature: Nej

Diverter flap actuator position motor alignment: OK

Target right air mix flap actuator motor position: 2692 steps

Right air mix flap actuator motor position: 2692 steps

Stored right air mix flap adjustment motor travel: 2692 steps

Current right air mix flap adjustment motor travel: 2740 steps

Lost communication between AAC pushbutton control module and right air mix flap motor: Nej

Right air mix flap motor electrical fault: Nej

Right air mix flap motor mechanical fault: Nej

Right air mix flap motor excess temperature: Nej

Right air mix flap motor position motors aligment: OK

Target left air mix flap motor position: 2675 steps

Left air mix flap motor position: 2675 steps

Stored left air mix flap adjustment motor travel: 2675 steps

Current left air mix flap adjustment motor travel: 2715 steps

Lost communication between AAC pushbutton control module and left air mix flap motor: Nej

Left air mix flap motor electrical fault: Nej

Left air mix flap motor mechanical fault: Nej

Left air mix flap motor excess temperature: Nej

Left air mix flap motor position motors alignment: OK

Target right defroster flap motor position: 1731 steps

Right defroster flap motor position: 1731 steps

Stored right defroster flap adjustment motor travel: 1731 steps

Current right defroster flap adjustment motor travel: 1810 steps

Lost communication between AAC pushbutton control module and right defroster flap motor: Nej

Right defroster flap actuator electrical fault: Nej

Right defroster flap motor mechanical fault: Nej

Right defroster flap actuator excess temperature: Nej

Right defroster flap actuator position motors alignment: OK

Target left defroster flap motor position: 1552 steps

Left defroster flap actuator motor position: 1552 steps

Stored left defroster flap adjustment motor travel: 1552 steps

Current left defroster flap adjustment motor travel: 1648 steps

Lost communication between AAC pushbutton control module and left defroster flap motor: Nej

Left defroster flap actuator electrical fault: Nej

Left defroster flap motor mechanical fault: Nej

Left defroster flap actuator excess temperature: Nej

Left defroster flap actuator position motors aligment: OK

Target right footwell flap motor position: 1203 steps

Right footwell flap motor position: 1203 steps

Stored right footwell flap adjustment motor travel: 1203 steps

Current right footwell flap adjustment motor travel: 1289 steps

Lost communication between AAC pushbutton control module and right footwell flap motor: Nej

Right footwell flap motor electrical fault: Nej

Right footwell flap motor mechanical fault: Nej

Right footwell flap motor excess temperature: Nej

Right footwell flap motor position motor alignment: OK

Target left footwell flap actuator motor position: 1157 steps

Left footwell flap motor position: 1157 steps

Stored left footwell flap adjustment motor travel: 1157 steps

Current left footwell flap adjustment motor travel: 1248 steps

Lost communication between AAC pushbutton control module and left footwell flap motor: Nej

Left footwell flap actuator electrical fault: Nej

Left footwell flap motor mechanical fault: Nej

Left footwell flap actuator excess temperature: Nej

Left footwell flap actuator position motor alignment: OK

Set position of right side ventilation air flap actuator motor: 0 steps

Actual position of right side ventilation air flap actuator motor: 0 steps

Stored right side ventilation air flap adjustment motor travel: 1523 steps

Current right side ventilation air flap adjustment motor travel: 1531 steps

Lost communication between AAC pushbutton control module and right side ventilation air flap motor: Nej

Right side ventilation air flap motor electrical fault: Nej

Right side ventilation air flap motor mechanical fault: Nej

Right side ventilation air flap motor excess temperature: Nej

Right side ventilation air flap motor position motor alignment: OK

Set position of left side ventilation air flap actuator motor: 0 steps

Actual position of left side ventilation air flap motor: 0 steps

Stored left side ventilation air flap adjustment motor travel: 1479 steps

Current left side ventilation air flap adjustment motor travel: 1532 steps

Lost communication between AAC pushbutton control module and left side ventilation air flap motor: Nej

Left side ventilation air flap motor electrical fault: Nej

Left side ventilation air flap motor mechanical fault: Nej

Left side ventilation air flap motor excess temperature: Nej

Left side ventilation air flap motor position motor alignment: OK

Target value of fresh/recirculation air flap motor: 1099 steps

Fresh/recirculation air flap motor: 1099 steps

Stored fresh and recirculated air flaps adjustment motor travel: 1099 steps

Current fresh and recirculated air flaps adjustment motor travel: 1196 steps

Lost communication between AAC pushbutton control module and fresh and recirculated air flaps motor: Nej

Fresh and recirculation air flaps motor electrical fault: Nej

Fresh and recirculation air flaps motor mechanical fault: Nej

Fresh and recirculation air flaps motor excess temperature: Nej

Fresh and recirculation air flaps motor position motor alignment: OK

Rest button: betjenes

On/Off button: Not operated

AC-OFF (EC) button: betjenes

REC button: Not operated

Defroster button: betjenes

Pushbutton for rear window defroster: Not operated

Temperature: basic setting: Decrease 4 °C

Blower: basic setting: Decrease 10%

Udgangs test

Controls

Left defroster flap motor

Right defroster flap motor

Left footwell flap motor

Right footwell flap motor

Left side ventilation air flap motor

Right side ventilation air flap actuator motor

Fresh and recirculation air flaps motor

Blæsermotor

Heat exchanger shutoff motor

Engine/AC electric suction fan

A/C compressor relay

Blower of interior temperature sensor

Illumination