PKW, MERCEDES, S 221, 221.073 S 550 CGI, Stationary heater (STH)

Klimaregelung - Stationary heater (STH) - 0

Identifikation

MB Hardwarenummer: 2215061098

Diagnoseversion: 18.4

Hardwarenummer: 07.02

Softwarenummer: 08.33

Lieferant: Webasto

Diagnoseversion: 12 04

Fehlercode

9151: Fault interlock has been activated

Controls

Fehlercode löschen

Ist-Werte

Spannungsversorgung: 12 V

Wassertemperatur: 80 °C

CO2 setting of combustion air blower: 192

Stationary heater in heating mode: Aktiv

Stationary heater in ventilation mode: Nicht aktiv

STH or HB heater unit: Aktiv

Operating state: Control interval

STH switchover valve: Nicht aktiv

STH switchover valve on/off ratio: 51.0

A6m2 (combustion air blower): Nicht aktiv

Flame monitor glowpin unit: Nicht aktiv

Flame monitor glowpin unit on/off ratio: 96.0

Flame monitor glowpin unit has flame detected: Ja

STH fuel metering pump: Nicht aktiv

STH fuel metering pump: 0.510 sec

On signal to telestart receiver: Nicht aktiv

Off signal to telestart receiver: Nicht aktiv

N72/1s30 (STH/HB [ZUB]/residual heat button): Not operated

On signal from the telestart receiver: Nein

Off signal from the telestart receiver: Nein

Stellgliedtest

Controls

Standheizung einschalten (Normalmodus)

Standheizung einschalten (Testmodus)

Heating/Switch on ventilation in line with request from AC pushbutton control module

Konfiguration

Controls

Konfiguration ändern