PKW, MERCEDES, R 251, 251.021 R 300 CDI, Stationary heater (STH)

Klimaregelung - Stationary heater (STH) - 0

Identifikation

MB Hardwarenummer: 2218705187

Diagnoseversion: 2.1

Hardwarenummer: 06.27

Softwarenummer: 06.43

Lieferant: Temic

Diagnoseversion: 02 01

Fehlercode

9053: Flame has gone out more than 4 times during the heating cycle

Controls

Fehlercode löschen

Ist-Werte

Versorgungsspannung: 10 V

Wassertemperatur: 101 °C

CO2 setting of combustion air blower: 129

Stationary heater in heating mode: Aktiv

Stationary heater in ventilation mode: Aktiv

STH heater unit: Aktiv

Operating state: Teillast

STH switchover valve: Aktiv

STH switchover valve on/off ratio: 96

Verbrennungsluftgebläse: Aktiv

Off signal to telestart receiver: Aktiv

Fuel preheating system: Aktiv

Fuel preheating system on/off ratio: 23

Flame monitor glowpin unit: Aktiv

Flame monitor glowpin unit on/off ratio: 85

Flame monitor glowpin unit has flame detected: Ja

Auxiliary heater metering pump: Aktiv

Auxiliary heater metering pump period: 1.170 sec

On signal to telestart receiver: Aktiv

STH switch: Operated

Number of teach-in processes in STH radio remote control receiver: 11

On signal from the telestart receiver: Ja

Off signal from the telestart receiver: Ja

Konfiguration

Controls

Konfiguration ändern