PKW, MERCEDES, R 251, 251.065 R 350 4MATIC, Klimatisierungsautomatik (AAC)

Klimaregelung - Klimatisierungsautomatik (AAC) - 0

Identifikation

MB Hardwarenummer: 2518206489

Diagnoseversion: 0.37

Hardwarenummer: 07.14

Softwarenummer: 07.45

Lieferant: Hella

Diagnoseversion: 00 25

Fehlercode

Event 900E: Klemme 30 - Spannung niedrig

9403: Rear shutoff flap motor LIN bus communication error

9604: Fehler: PTC, Keine Kommunikation (LIN)

Controls

Fehlercode löschen

Ist-Werte

Fresh/recirculation air flap motor: 100 %

Target value of fresh/recirculation air flap motor: 100 %

Fresh/recirculation air flap motor: 1611 Schritte

Target value of fresh/recirculation air flap motor: 1611 Schritte

Stored fresh and recirculated air flaps adjustment motor travel: 1611 Schritte

Current fresh and recirculated air flaps adjustment motor travel: 1611 Schritte

Fresh and recirculation air flaps motor manufacturer: Elmos/Saia

Left air mix flap motor position: 88 %

Target left air mix flap motor position: 89 %

Left air mix flap motor position: 1207 Schritte

Target left air mix flap motor position: 1212 Schritte

Stored left air mix flap adjustment motor travel: 1362 Schritte

Current left air mix flap adjustment motor travel: 1362 Schritte

Left air mix flap motor manufacturer: Elmos/Saia

Right air mix flap actuator motor position: 91 %

Target right air mix flap actuator motor position: 91 %

Right air mix flap actuator motor position: 1126 Schritte

Target right air mix flap actuator motor position: 1131 Schritte

Stored right air mix flap adjustment motor travel: 1238 Schritte

Current right air mix flap adjustment motor travel: 1238 Schritte

Right air mix flap motor manufacturer: Elmos/Saia

Rear shutoff flap actuator motor position: 68 %

Target rear shutoff flap actuator motor position: 68 %

Rear shutoff flap actuator motor position: 1914 Schritte

Target rear shutoff flap actuator motor position: 1921 Schritte

Stored rear shutoff flap adjustment motor travel: 2800 Schritte

Current rear shutoff flap adjustment motor travel: 2800 Schritte

Rear shutoff flap motor manufacturer: Elmos/Saia

Center ventilation air flap actuator motor position: 59 %

Target center ventilation air flap actuator motor position: 59 %

Center ventilation air flap actuator motor position: 855 Schritte

Target center ventilation air flap actuator motor position: 852 Schritte

Stored center ventilation air flap adjustment motor travel: 1431 Schritte

Current center ventilation air flap adjustment motor travel: 1431 Schritte

Center ventilation air flap motor manufacturer: Nicht benutzt

Left and right footwell flaps motor position: 100 %

Target left and right footwell flaps motor position: 100 %

Left and right footwell flaps motor position: 1050 Schritte

Target left and right footwell flaps motor position: 1050 Schritte

Stored left and right footwell flaps adjustment motor travel: 1050 Schritte

Current left and right footwell flaps adjustment motor travel: 1050 Schritte

Hersteller Stellmotor für Fußraumklappe links und rechts: Elmos/Saia

Left and right defroster flaps motor position: 100 %

Target left and right defroster flaps motor position: 100 %

Left and right defroster flaps motor position: 1467 Schritte

Target left and right defroster flaps motor position: 1467 Schritte

Stored left and right defroster flaps adjustment motor travel: 1467 Schritte

Current left and right defroster flaps adjustment motor travel: 1467 Schritte

Hersteller Stellmotor für Defrostklappe links und rechts: Elmos/Saia

Rear air distribution flap actuator motor position: 0 %

Target rear air distribution flap actuator motor position: 0 %

Rear air distribution flap actuator motor position: 0 Schritte

Target rear air distribution flap actuator motor position: 0 Schritte

Stored rear air distribution flap adjustment motor travel: 832 Schritte

Current rear air distribution flap adjustment motor travel: 832 Schritte

Rear air distribution flap motor manufacturer: Elmos/Saia

Interior air temperature sensor: 23 °C

Geber für Außentemperatur: 22 °C

Verdampfertemperatur vorn: 22 °C

Left side outlet temperature sensor: 24 °C

Right side outlet temperature sensor: 21 °C

Temperatursensor Fußraum links: 20 °C

Temperatursensor Fußraum rechts: 18 °C

Left center outlet temperature sensor: 35 °C

Right center outlet temperature sensor: 35 °C

Center rear interior temperature sensor: 24 °C

Kältemitteldruck: 2 Bar

Sonnensensor, Lichtintensität: 255 %

Klemme 30: 14 V

Sensor-Versorgungsspannung: 5 V

Request to A/C compressor: 0 %

Geber für Kühlmitteltemperatur: 91 °C

Motordrehzahl: 637 UpM

Rear air conditioning refrigerant shutoff valve: AUS

Heating water circulation pump: EIN

Compressor status or cause for compressor cutout: Button 'OFF' operated

Front blower capacity: 0 %

Front blower supply voltage: 0 V

Front blower motor: 0 A

Stellgliedtest

Controls

Stellmotor für Frisch-/Umluftklappe

Left air mix flap motor

Right air mix flap motor

Rear shutoff flap positioning motor

Stellmotor für Defrostklappe links und rechts

Stellmotor für Fußraumklappe links und rechts

Center ventilation flap motor

Diverter flap actuator motor

Rear air distribution flap positioning motor

Gebläsemotor

Elektrischer Sauglüfter

Beleuchtung

AC compressor

Heating water circulation pump

Closing air recirculation flap (for cleaning)