PKW, MERCEDES, R 251, 251.122 R 320 CDI LL 4MATIC, Klimatisierungsautomatik (AAC)
Klimaregelung - Klimatisierungsautomatik (AAC) - 0
Identifikation
MB Hardwarenummer: 2518206489
Diagnoseversion: 0.37
Hardwarenummer: 07.14
Softwarenummer: 07.45
Lieferant: Hella
Diagnoseversion: 00 25
Fehlercode
Event 900E: Klemme 30 - Spannung niedrig
9403: Rear shutoff flap motor LIN bus communication error
9604: Fehler: PTC, Keine Kommunikation (LIN)
Controls
Fehlercode löschen
Ist-Werte
Fresh/recirculation air flap motor: 100 %
Target value of fresh/recirculation air flap motor: 100 %
Fresh/recirculation air flap motor: 1611 Schritte
Target value of fresh/recirculation air flap motor: 1611 Schritte
Stored fresh and recirculated air flaps adjustment motor travel: 1611 Schritte
Current fresh and recirculated air flaps adjustment motor travel: 1611 Schritte
Fresh and recirculation air flaps motor manufacturer: Elmos/Saia
Left air mix flap motor position: 88 %
Target left air mix flap motor position: 89 %
Left air mix flap motor position: 1207 Schritte
Target left air mix flap motor position: 1212 Schritte
Stored left air mix flap adjustment motor travel: 1362 Schritte
Current left air mix flap adjustment motor travel: 1362 Schritte
Left air mix flap motor manufacturer: Elmos/Saia
Right air mix flap actuator motor position: 91 %
Target right air mix flap actuator motor position: 91 %
Right air mix flap actuator motor position: 1126 Schritte
Target right air mix flap actuator motor position: 1131 Schritte
Stored right air mix flap adjustment motor travel: 1238 Schritte
Current right air mix flap adjustment motor travel: 1238 Schritte
Right air mix flap motor manufacturer: Elmos/Saia
Rear shutoff flap actuator motor position: 68 %
Target rear shutoff flap actuator motor position: 68 %
Rear shutoff flap actuator motor position: 1914 Schritte
Target rear shutoff flap actuator motor position: 1921 Schritte
Stored rear shutoff flap adjustment motor travel: 2800 Schritte
Current rear shutoff flap adjustment motor travel: 2800 Schritte
Rear shutoff flap motor manufacturer: Elmos/Saia
Center ventilation air flap actuator motor position: 59 %
Target center ventilation air flap actuator motor position: 59 %
Center ventilation air flap actuator motor position: 855 Schritte
Target center ventilation air flap actuator motor position: 852 Schritte
Stored center ventilation air flap adjustment motor travel: 1431 Schritte
Current center ventilation air flap adjustment motor travel: 1431 Schritte
Center ventilation air flap motor manufacturer: Nicht benutzt
Left and right footwell flaps motor position: 100 %
Target left and right footwell flaps motor position: 100 %
Left and right footwell flaps motor position: 1050 Schritte
Target left and right footwell flaps motor position: 1050 Schritte
Stored left and right footwell flaps adjustment motor travel: 1050 Schritte
Current left and right footwell flaps adjustment motor travel: 1050 Schritte
Hersteller Stellmotor für Fußraumklappe links und rechts: Elmos/Saia
Left and right defroster flaps motor position: 100 %
Target left and right defroster flaps motor position: 100 %
Left and right defroster flaps motor position: 1467 Schritte
Target left and right defroster flaps motor position: 1467 Schritte
Stored left and right defroster flaps adjustment motor travel: 1467 Schritte
Current left and right defroster flaps adjustment motor travel: 1467 Schritte
Hersteller Stellmotor für Defrostklappe links und rechts: Elmos/Saia
Rear air distribution flap actuator motor position: 0 %
Target rear air distribution flap actuator motor position: 0 %
Rear air distribution flap actuator motor position: 0 Schritte
Target rear air distribution flap actuator motor position: 0 Schritte
Stored rear air distribution flap adjustment motor travel: 832 Schritte
Current rear air distribution flap adjustment motor travel: 832 Schritte
Rear air distribution flap motor manufacturer: Elmos/Saia
Interior air temperature sensor: 23 °C
Geber für Außentemperatur: 22 °C
Verdampfertemperatur vorn: 22 °C
Left side outlet temperature sensor: 24 °C
Right side outlet temperature sensor: 21 °C
Temperatursensor Fußraum links: 20 °C
Temperatursensor Fußraum rechts: 18 °C
Left center outlet temperature sensor: 35 °C
Right center outlet temperature sensor: 35 °C
Center rear interior temperature sensor: 24 °C
Kältemitteldruck: 2 Bar
Sonnensensor, Lichtintensität: 255 %
Klemme 30: 14 V
Sensor-Versorgungsspannung: 5 V
Request to A/C compressor: 0 %
Geber für Kühlmitteltemperatur: 91 °C
Motordrehzahl: 637 UpM
Rear air conditioning refrigerant shutoff valve: AUS
Heating water circulation pump: EIN
Compressor status or cause for compressor cutout: Button 'OFF' operated
Front blower capacity: 0 %
Front blower supply voltage: 0 V
Front blower motor: 0 A
Stellgliedtest
Controls
Stellmotor für Frisch-/Umluftklappe
Left air mix flap motor
Right air mix flap motor
Rear shutoff flap positioning motor
Stellmotor für Defrostklappe links und rechts
Stellmotor für Fußraumklappe links und rechts
Center ventilation flap motor
Diverter flap actuator motor
Rear air distribution flap positioning motor
Gebläsemotor
Elektrischer Sauglüfter
Beleuchtung
AC compressor
Heating water circulation pump
Closing air recirculation flap (for cleaning)