PKW, MERCEDES, R 251, 251.020 R 280 CDI 4MATIC, Adaptive damping system (ADS)
Dämpfungssystem - Adaptive damping system (ADS) - 0
Identifikation
Herstellungsdatum: 00 00 00
Hardwarenummer: 22.06
Softwarenummer: 50.06
Diagnoseversion: 5.3
MB Hardwarenummer: 25 15 45 20 32
Lieferant: Temic
Identifikator: 05 03
Fehlercode
5000: Airmatic control module malfunction
5350: Check airmatic pressure release valve
Controls
Fehlercode löschen
Ist-Werte
Klemme 30: 11 V
Klemme 87: AUS
Lock position: Nein
Compressor locked due to switch-on time limit: Ja
Höhensensor vorne links: 3.49 V
Left front vehicle level: 44 mm
Höhensensor vorne rechts: 1.31 V
Right front vehicle level: 188 mm
Höhenregelsensor hinten links: 1.90 V
Vehicle level at rear left: 209 mm
Höhensensor hinten rechts: 3.27 V
Vehicle level at rear right: 214 mm
AIRmatic pressure sensor: 7 Bar
Geber für Karosseriebeschleunigung vorne links: 490 mV
Geber für Karosseriebeschleunigung vorne rechts: 2843 mV
Compressor use times: 2271560481 sec
National version: Rest of World
Kraftfahrzeugmodell: X164
Left front axle damping solenoid valve 1: 520 mA
Left front axle damping solenoid valve 2: 510 mA
Right front axle damping solenoid valve 1: 1284 mA
Left rear axle damping solenoid valve 1: 382 mA
Left rear axle damping solenoid valve 2: 1275 mA
Right rear axle damping solenoid valve 1: 706 mA
Right rear axle damping solenoid valve 2: 843 mA
Dienstprogramme
Controls
Release pressure in central reservoir
Fill central reservoir
Left front damper valves
Right front damper valves
Left rear damper valves
Right rear damper valves
Kalibrierten Wert anfahren (automatisch)
Kalibrierten Wert anfahren (manuell)
Pneumatic test of AIRmatic compressor unit
Pneumatic test of left front level control valve
Pneumatic test of right front level control valve
Pneumatic test of left rear level control valve
Pneumatic test of right rear level control valve
Pneumatischer Test des AIRmatic Füllventils für Zentralbehälter
Pneumatischer Test des AIRmatic Druckablassventils
Leakage test between compressor and valve block
Reset compressor operating time