PKW, MERCEDES, M 164, 164.120 ML 280, 300 CDI 4MATIC, Adaptive damping system (ADS)

Dämpfungssystem - Adaptive damping system (ADS) - 0

Identifikation

Herstellungsdatum: 00 00 00

Hardwarenummer: 22.06

Softwarenummer: 50.06

Diagnoseversion: 5.3

MB Hardwarenummer: 25 15 45 20 32

Lieferant: Temic

Identifikator: 05 03

Fehlercode

5000: Airmatic control module malfunction

5350: Check airmatic pressure release valve

Controls

Fehlercode löschen

Ist-Werte

Klemme 30: 11 V

Klemme 87: AUS

Lock position: Nein

Compressor locked due to switch-on time limit: Ja

Höhensensor vorne links: 3.49 V

Left front vehicle level: 44 mm

Höhensensor vorne rechts: 1.31 V

Right front vehicle level: 188 mm

Höhenregelsensor hinten links: 1.90 V

Vehicle level at rear left: 209 mm

Höhensensor hinten rechts: 3.27 V

Vehicle level at rear right: 214 mm

AIRmatic pressure sensor: 7 Bar

Geber für Karosseriebeschleunigung vorne links: 490 mV

Geber für Karosseriebeschleunigung vorne rechts: 2843 mV

Compressor use times: 2271560481 sec

National version: Rest of World

Kraftfahrzeugmodell: X164

Left front axle damping solenoid valve 1: 520 mA

Left front axle damping solenoid valve 2: 510 mA

Right front axle damping solenoid valve 1: 1284 mA

Left rear axle damping solenoid valve 1: 382 mA

Left rear axle damping solenoid valve 2: 1275 mA

Right rear axle damping solenoid valve 1: 706 mA

Right rear axle damping solenoid valve 2: 843 mA

Dienst­programme

Controls

Release pressure in central reservoir

Fill central reservoir

Left front damper valves

Right front damper valves

Left rear damper valves

Right rear damper valves

Kalibrierten Wert anfahren (automatisch)

Kalibrierten Wert anfahren (manuell)

Pneumatic test of AIRmatic compressor unit

Pneumatic test of left front level control valve

Pneumatic test of right front level control valve

Pneumatic test of left rear level control valve

Pneumatic test of right rear level control valve

Pneumatischer Test des AIRmatic Füllventils für Zentralbehälter

Pneumatischer Test des AIRmatic Druckablassventils

Leakage test between compressor and valve block

Reset compressor operating time