Bil, MERCEDES, M 164, 164.186 ML 350 4MATIC, Automatic air conditioning (AAC)
Klima Anlæg - Automatic air conditioning (AAC) - 0
Identifikation
MB number for hardware: 2518206489
Diagnose version: 0.37
Hardware number: 07.14
Software nummer: 07.45
Supplier: Hella
Diagnose version: 00 25
Fejlkoder
Event 900E: Terminal 30 low voltage
9403: Rear shutoff flap motor LIN bus communication error
9604: Fehler: PTC, Keine Kommunikation (LIN)
Controls
Clear DTC
Levende Data
Fresh/recirculation air flap motor: 100 %
Target value of fresh/recirculation air flap motor: 100 %
Fresh/recirculation air flap motor: 1611 steps
Target value of fresh/recirculation air flap motor: 1611 steps
Stored fresh and recirculated air flaps adjustment motor travel: 1611 steps
Current fresh and recirculated air flaps adjustment motor travel: 1611 steps
Fresh and recirculation air flaps motor manufacturer: Elmos/Saia
Left air mix flap motor position: 88 %
Target left air mix flap motor position: 89 %
Left air mix flap motor position: 1207 steps
Target left air mix flap motor position: 1212 steps
Stored left air mix flap adjustment motor travel: 1362 steps
Current left air mix flap adjustment motor travel: 1362 steps
Left air mix flap motor manufacturer: Elmos/Saia
Right air mix flap actuator motor position: 91 %
Target right air mix flap actuator motor position: 91 %
Right air mix flap actuator motor position: 1126 steps
Target right air mix flap actuator motor position: 1131 steps
Stored right air mix flap adjustment motor travel: 1238 steps
Current right air mix flap adjustment motor travel: 1238 steps
Right air mix flap motor manufacturer: Elmos/Saia
Rear shutoff flap actuator motor position: 68 %
Target rear shutoff flap actuator motor position: 68 %
Rear shutoff flap actuator motor position: 1914 steps
Target rear shutoff flap actuator motor position: 1921 steps
Stored rear shutoff flap adjustment motor travel: 2800 steps
Current rear shutoff flap adjustment motor travel: 2800 steps
Rear shutoff flap motor manufacturer: Elmos/Saia
Center ventilation air flap actuator motor position: 59 %
Target center ventilation air flap actuator motor position: 59 %
Center ventilation air flap actuator motor position: 855 steps
Target center ventilation air flap actuator motor position: 852 steps
Stored center ventilation air flap adjustment motor travel: 1431 steps
Current center ventilation air flap adjustment motor travel: 1431 steps
Center ventilation air flap motor manufacturer: Ikke anvendt
Left and right footwell flaps motor position: 100 %
Target left and right footwell flaps motor position: 100 %
Left and right footwell flaps motor position: 1050 steps
Target left and right footwell flaps motor position: 1050 steps
Stored left and right footwell flaps adjustment motor travel: 1050 steps
Current left and right footwell flaps adjustment motor travel: 1050 steps
Left and right footwell flaps motor manufacturer: Elmos/Saia
Left and right defroster flaps motor position: 100 %
Target left and right defroster flaps motor position: 100 %
Left and right defroster flaps motor position: 1467 steps
Target left and right defroster flaps motor position: 1467 steps
Stored left and right defroster flaps adjustment motor travel: 1467 steps
Current left and right defroster flaps adjustment motor travel: 1467 steps
Left and right defroster flaps motor manufacturer: Elmos/Saia
Rear air distribution flap actuator motor position: 0 %
Target rear air distribution flap actuator motor position: 0 %
Rear air distribution flap actuator motor position: 0 steps
Target rear air distribution flap actuator motor position: 0 steps
Stored rear air distribution flap adjustment motor travel: 832 steps
Current rear air distribution flap adjustment motor travel: 832 steps
Rear air distribution flap motor manufacturer: Elmos/Saia
Interior air temperature sensor: 23 °C
Ambient temperature sensor: 22 °C
Front evaporator temperature: 22 °C
Left side outlet temperature sensor: 24 °C
Right side outlet temperature sensor: 21 °C
Left footwell temperature sensor: 20 °C
Right footwell temperature sensor: 18 °C
Left center outlet temperature sensor: 35 °C
Right center outlet temperature sensor: 35 °C
Center rear interior temperature sensor: 24 °C
Refrigerant pressure: 2 bar
Sun sensor light intensity: 255 %
Terminal 30 : 14 V
Supply voltage for sensor: 5 V
Request to A/C compressor: 0 %
Motor kølevæske temperatur føler: 91 °C
Motor Hastighed: 637 Omdr.
Rear air conditioning refrigerant shutoff valve: Sluk
Heating water circulation pump: Tænd
Compressor status or cause for compressor cutout: Button 'OFF' operated
Front blower capacity: 0 %
Front blower supply voltage: 0 V
Front blower motor: 0 A
Udgangs test
Controls
Fresh and recirculation air flaps motor
Left air mix flap motor
Right air mix flap motor
Rear shutoff flap positioning motor
Left and right defroster flaps motor
Left and right footwell flaps motor
Center ventilation flap motor
Diverter flap actuator motor
Rear air distribution flap positioning motor
Blæsermotor
Electric suction fan
Illumination
AC compressor
Heating water circulation pump
Closing air recirculation flap (for cleaning)