PKW, MERCEDES, M 163, 163.174 ML 55 AMG, Klimatisierungsautomatik (AAC)
Klimaregelung - Klimatisierungsautomatik (AAC) - 0
Identifikation
Herstellungsdatum: 02 09 26
Hardwarenummer: 22.02
Softwarenummer: 22.02
Diagnoseversion: 129.0
MB Hardwarenummer: 16 38 20 42 89
Lieferant: Hella
Identifikator: 81 00
Fehlercode
B1001: Electronic control unit (ECU) - defective
B1206: Rear shutoff flap positioning motor
B1304: Fault in CAN communication with all-activity module (AAM)
B1305: Fault in CAN communication with extended activity module (EAM)
Controls
Fehlercode löschen
Ist-Werte
In-car temperature sensor: 5.5 °C
Rear blower: 11.6 V
Geber für Verdampfertemperatur: 20.8 °C
Geber für Kältemitteldruck und Kältemitteltemperatur: 14.5 Bar
Geber für Kältemitteldruck und Kältemitteltemperatur: 30.0 °C
Rear outlet air temperature sensor: 33.5 °C
Front footwell outlet air temperature sensor: 66.0 °C
Center vent outlet air temperature sensor: 17.5 °C
Sun sensor: 84.0 %
Spannungsversorgung: 20.6 V
AC compressor: 48.0 %
Gebläsemotor: 76.0 %
Gebläsemotor: Erreicht
Blower motor level (Rear): 98.0 %
Stationary heater: AUS
Heater booster: AUS
Heating water circulation pump: AUS
Rear window defroster switch: AUS
Center vent flap position: 30227
Set position of center vent flap actuator motor: 22020
Stored center outlet flap adjustment motor travel: 25703
Current center outlet flap adjustment motor travel: 69
Left air mix flap position: 22272
Set position of left air mix flap actuator motor: 17412
Stored left air mix flap adjustment motor travel: 17970
Current left air mix flap adjustment motor travel: 102
Positionierung Antriebsmotor Defroster-Klappe : 30792
Set position of defroster flap actuator motor: 17668
Stored defroster flap adjustment motor travel: 33287
Current defroster flap adjustment motor travel: 8
Footwell flap position: 21766
Set position of footwell flap actuator motor: 30260
Stored footwell flap adjustment motor travel: 29704
Current footwell flap adjustment motor travel: 0
Fresh air and recirculated air flap position: 22272
Set position of fresh and recirculated air flap actuator motor: 22131
Stored fresh and recirculated air flaps adjustment motor travel: 25348
Current fresh and recirculated air flaps adjustment motor travel: 3
Rear shutoff flap actuator motor position: 29765
Set position of rear shutoff flap actuator motor: 25862
Stored rear shutoff flap adjustment motor travel: 22391
Current rear shutoff flap adjustment motor travel: 7
Rear air distribution flap position: 14083
Set position of rear air distribution flap motor: 12804
Stored rear air distribution flap adjustment motor travel: 30724
Current rear air distribution flap adjustment motor travel: 134
Blower regulator: short circuit cutoff: Inaktiv
Blower regulator: maximum current limit: Inaktiv
Blower regulator: 100%: Inaktiv
Blower regulator: overload - shutoff: Inaktiv
Blower regulator temperature: In Ordnung
Blower regulator: supply voltage (under- or overvoltage): Inaktiv
Blower regulator: output stage: Inaktiv
Blower regulator: 26 A
Blower regulator: 150.0 °C
Heating systems recirculated air unit: 13 V
Stellgliedtest
Controls
Defroster flap
Footwell flap
Center outlet flap
Fresh air/recirculation air flow flap
Rear shutoff flap
Rear air distribution flap
Gebläsemotor
Lüftungsmotor (hinten)
Beleuchtung
Heating water circulation pump
Klimakompressor
Rear window defroster test
Dienstprogramme
Controls
Normalizing of positioning motors
Check of adjustment range of positioning motors
Konfiguration
Controls
Konfiguration ändern