Όχημα, MERCEDES, M 163, 163.172 ML 430, Automatic air conditioning (AAC)

Έλεγχος κλιματισμού - Automatic air conditioning (AAC) - 0

Αναγνώριση

Ημερομηνία κατασκευής: 02 09 26

Αριθμός υλικολογισμικού: 22.02

Αριθμός λογισμικού: 22.02

Έκδοση διάγνωσης: 129.0

MB αριθμός υλικολογισμικού: 16 38 20 42 89

Προμηθευτής: Hella

Αναγνωριστικό: 81 00

Κωδικοί Βλαβών

B1001: Electronic control unit (ECU) - defective

B1206: Rear shutoff flap positioning motor

B1304: Fault in CAN communication with all-activity module (AAM)

B1305: Fault in CAN communication with extended activity module (EAM)

Controls

Διαγραφή κωδικών

Ροή δεδομένων

In-car temperature sensor: 5.5 °C

Rear blower: 11.6 V

Αισθητήρας θερμοκρασίας εξατμιστή: 20.8 °C

Refrigerant pressure and temperature sensor: 14.5 bar

Refrigerant pressure and temperature sensor: 30.0 °C

Rear outlet air temperature sensor: 33.5 °C

Front footwell outlet air temperature sensor: 66.0 °C

Center vent outlet air temperature sensor: 17.5 °C

Sun sensor: 84.0 %

Τροφοδοσία τάσης: 20.6 V

AC compressor: 48.0 %

Μοτέρ βεντιλατέρ: 76.0 %

Μοτέρ βεντιλατέρ: Επιτεύχθηκε

Blower motor level (Rear): 98.0 %

Στατικός θερμαντής: Εκτός

Heater booster: Εκτός

Αντλία κυκλοφορίας νερού θέρμανσης: Εκτός

Rear window defroster switch: Εκτός

Center vent flap position: 30227

Set position of center vent flap actuator motor: 22020

Stored center outlet flap adjustment motor travel: 25703

Current center outlet flap adjustment motor travel: 69

Left air mix flap position: 22272

Set position of left air mix flap actuator motor: 17412

Stored left air mix flap adjustment motor travel: 17970

Current left air mix flap adjustment motor travel: 102

Defroster flap actuator motor position: 30792

Set position of defroster flap actuator motor: 17668

Stored defroster flap adjustment motor travel: 33287

Current defroster flap adjustment motor travel: 8

Footwell flap position: 21766

Set position of footwell flap actuator motor: 30260

Stored footwell flap adjustment motor travel: 29704

Current footwell flap adjustment motor travel: 0

Fresh air and recirculated air flap position: 22272

Set position of fresh and recirculated air flap actuator motor: 22131

Stored fresh and recirculated air flaps adjustment motor travel: 25348

Current fresh and recirculated air flaps adjustment motor travel: 3

Rear shutoff flap actuator motor position: 29765

Set position of rear shutoff flap actuator motor: 25862

Stored rear shutoff flap adjustment motor travel: 22391

Current rear shutoff flap adjustment motor travel: 7

Θέση κλαπέ διανομής αέρα πίσω: 14083

Set position of rear air distribution flap motor: 12804

Stored rear air distribution flap adjustment motor travel: 30724

Current rear air distribution flap adjustment motor travel: 134

Blower regulator: short circuit cutoff: Ανενεργό

Blower regulator: maximum current limit: Ανενεργό

Blower regulator: 100%: Ανενεργό

Blower regulator: overload - shutoff: Ανενεργό

Blower regulator temperature: Εντάξει

Blower regulator: supply voltage (under- or overvoltage): Ανενεργό

Blower regulator: output stage: Ανενεργό

Blower regulator: 26 A

Blower regulator: 150.0 °C

Heating systems recirculated air unit: 13 V

Δοκιμή ενεργο­ποιητών

Controls

Κλαπέ απόψυξης

Κλαπέ χώρου ποδιών

Κεντρικό κλαπέ εξαγωγής

Φρέσκος αέρας/ανακυκλοφορίας αέρα κλαπέ ροής

Rear shutoff flap

Πίσω κλαπέ διανομής αέρα

Μοτέρ βεντιλατέρ

Μοτέρ βεντιλατέρ (πίσω)

Φωτισμός

Αντλία κυκλοφορίας νερού θέρμανσης

Συμπιεστής A/C

Rear window defroster test

Βοηθήματα

Controls

Normalizing of positioning motors

Έλεγχος του εύρους ρύθμισης των βηματικών μοτέρ

Διαμόρφωση

Controls

Επεξεργασία ρυθμίσεων