PKW, MERCEDES, A 177, 177.144 A220, Klimatisierungsautomatik (AAC)
Klimaregelung - Klimatisierungsautomatik (AAC) - 0
Identifikation
Diagnoseversion: 00 10 09
Boot software number: 33.1.2
Hardware-Version: 0.0.0
Softwareversion: 33.1.2
Software version 1: --
Software version 2: --
Lieferant: --
Hardware-Teilenummer:
Software part number (customer): 0104482140
Software part number (code): --
Software part number (data): --
Seriennummer: --
FIN:
VIN stored:
Fehlercode
U011100: Communication with battery control unit - malfunction
Controls
Fehlercode löschen
Ist-Werte
Causes of refrigerant compressor shutoff: Klimakompressor eingeschaltet
B12 (Kältemittel-Drucksensor): 141.5 Bar
Geber für Verdampfertemperatur: 376.0 °C
Outside air temperature sensor: 19.0 °C
Außenlufttemperatur : 12 °C
Interior temperature sensor with integrated fan: 53.0 °C
Interior temperature sensor with integrated fan: Stationär
Kühlmitteltemperatur: 73.0 °C
Motordrehzahl: 702 UpM
Batteriespannung: 12.0 V
Blower regulator supply voltage: 12.0 V
Blower regulator current consumption: 1.01 A
Blower regulator temperature: 123.0 °C
Gebläsemotor-Spannung: 7.1 V
Pumpe für Kühlmittelumlauf: AUS
Permissible deviation between actual and specified temperatures: Nicht aktiv
Outside temperature is too high: Nicht aktiv
ECO start/stop function is deactivated: Nicht aktiv
There is a risk of sudden fogging of windshield and side windows: Nicht aktiv
Not initialized: Nicht aktiv
Function 'Defrost' is active: Nicht aktiv
Cooling in vehicle interior: Nicht aktiv
Diagnose: Nicht aktiv
Coding 'ECO start/stop function' is deactivated in AAC control and operating unit: Nicht aktiv
Data transfer error: Nicht aktiv
Temperature measured at component 'Evaporator' is too high: Nicht aktiv
AC compressor electromagnetic clutch: Offen
Electric refrigerant compressor status: ---
Electric refrigerant compressor: 13.83 V
High-voltage battery cooling system shutoff valve: Schließen
Fresh air/recirculated air flap actuator motor
Current flap adjustment range: 1432
Stored flap adjustment range: 1289
Actual position of actuator motor: -8585
Specified position of actuator motor: 10629
Current position of actuator motor: 5 %
Position of actuator motor specified by control unit: 100 %
Central air distribution actuator motor
Current flap adjustment range: 2408
Stored flap adjustment range: 84
Actual position of actuator motor: -9389
Specified position of actuator motor: -7881
Current position of actuator motor: 12 %
Position of actuator motor specified by control unit: 10 %
Right blend air flap actuator motor
Current flap adjustment range: 1159
Stored flap adjustment range: 1033
Actual position of actuator motor: 12679
Specified position of actuator motor: 8550
Current position of actuator motor: 5 %
Position of actuator motor specified by control unit: 53 %
Stellgliedtest
Controls
Gebläse
Elektrischer Kältemittelkompressor
Stellmotor für Frisch-/Umluftklappe
Central air distribution actuator motor
Right blend air flap actuator motor
Fan motor
High-voltage battery cooling system shutoff valve
Dienstprogramme
Controls
Normalization of actuator motors
Teach in actuator motors
Breaking-in of refrigerant compressor
Entriegeln Heizung
Konfiguration
Controls
Configuration coding
OBD coding
Comfort coding
Workshop storage