PKW, MERCEDES, GLE 167, 167.123 GLE 400 d 4MATIC, Getriebe (VGS)
Transaxle - Getriebe (VGS) - 0
Identifikation
Diagnoseversion: 00 09 A5
Boot software number: 0.0.0
Hardware-Version: 0.0.0
Softwareversion: --
Software version 1: --
Software version 2: --
Lieferant: --
Hardware-Teilenummer:
Software part number (customer): --
Software part number (code): --
Software part number (data): --
Seriennummer: --
FIN:
VIN stored:
Fehlercode
U140A00: Fahrzeuggeschwindigkeit, Raddrehzahlsensor vorn/rechts, Signaländerung: unplausibel
Controls
Fehlercode löschen
Ist-Werte
Zündzyklenzähler: 0
General denominator (IUMPR): 0
Torque converter slip speed: 354.0 UpM
Speed difference (target): 0.00 UpM
Target pressure Kueb: 0.00 mbar
Torque converter lock-up clutch status: Slipping
Position of selection range valve: Initialization value
Transmission mode: Sport
Calculated gear: Neutral position
Parking position: P
Sollgang: Gear change abort
Motordrehmoment: 2066.0 N·m
Converted moment: 0.0 N·m
Output speed: 5411.00 UpM
Function mode: Nein
Steering wheel shift button 'MINUS': Actuated
Steering wheel shift button 'PLUS': Not actuated
Oil pressure sensor of wet clutch: AUS
Startfreigabe: Nicht aktiv
Offroad: Nicht aktiv
Kickdown: Nicht aktiv
Emergency operation mode: Nein
Current error codes: Nein
Internal transmission speed: 0.00 UpM
Getriebeausgangsdrehzahl: 0.00 UpM
Turbine speed: 0.00 UpM
Motordrehzahl: 0.00 UpM
Raddrehzahlsensor vorn links: 0.00 UpM
Raddrehzahlsensor vorne rechts: 0.00 UpM
Raddrehzahlsensor hinten links: 0.00 UpM
Raddrehzahlsensor hinten rechts: 0.00 UpM
Rear speed: 0.00 km/h
Front speed: 0.00 km/h
Geber für Gaspedalstellung: 0
STEIGUNG: 0
Front speed: 0.00 km/h
Target pressure K1: 0.00 mbar
Target pressure B1: 0.00 mbar
Target pressure B3: 0.00 mbar
Target pressure K3: 0.00 mbar
Target pressure K2: 0.00 mbar
Target pressure B2/BR: 0.00 mbar
Target working pressure: 0.00 mbar
Target pressure KÜB/NAK: 0.00 mbar
Switching valve PnP (target): 0
Switching valve R-D (target): 0
Engine cooling water temperature: 0
Geschwindigkeit: 0.00 UpM
Phase current: 0.00 A
Counter for supported valves: 0
Status Ventil 0 (KUEB): Defekt
Current value Ventil 0 (KUEB): 0.00 mA
Status Ventil 1 (B08): Defekt
Current value Ventil 1 (B08): 0.00 mA
Status Ventil 2 (K81): Defekt
Current value Ventil 2 (K81): 0.00 mA
Status Ventil 3 (K38): Defekt
Current value Ventil 3 (K38): 0.00 mA
Status Ventil 4 (B05): Defekt
Current value Ventil 4 (B05): 0.00 mA
Status Ventil 5 (K27): Defekt
Current value Ventil 5 (K27): 0.00 mA
Status Ventil 6 (B06): Defekt
Current Ventil 6 (B06): 0.00 mA
Status Ventil 7 (AD): Defekt
Current Ventil 7 (AD): 0.00 mA
Status PnP: Defekt
Current value PnP: 0.00 mA
Status lift magnet: Defekt
Current lift magnet: 0.00 mA
Batteriespannung: 0.00 mV
AUX supply voltage: 0.00 mV
CPU supply voltage: 0.00 mV
1V Sensor supply voltage: 0.00 mV
2V Sensor supply voltage: 0.00 mV
3V Sensor supply voltage: 0.00 mV
4V Sensor supply voltage: 0.00 mV
Park lock sensor PWM raw signal value: 0.00 %
Park lock sensor position: 0.00 mm
Clutch sensor PWM raw signal value: 0.00 %
Geber für Kupplungsposition: 0.00 mm
Status K38 sensor: Defekt
Working pressure sensor: 0.00 mbar
Status NAK sensor: Defekt
Pressure sensor NAK value: 0.00 mbar
Chip temperature sensor: 0.0 °C
Chip temperature sensor 2: 0.0 °C
Betriebsart:
Dienstprogramme
Controls
Resetting the adaptation values of shift operations
Resetting of adaptation data (Torque converter lockup clutch)
Resetting of learned values of park pawl
Adaptation procedure for torque converter lockup clutch
Teach-in of position sensor of park pawl
Valve flushing
Switch off incline recognition for dynamometer mode
Konfiguration
Controls
Konfiguration ändern
Konfiguration 2 ändern
Edit configuration 3
Edit configuration 4