Bil, MERCEDES, GLE 167, 167.357 GLE 450 4MATIC, Right rear door (DCU-RR)

Dør moduler - Right rear door (DCU-RR) - 0

Identifikation

Diagnose version: 02 04 07

Boot software number: 10.32.0

Hardwareversion: 8.2.0

Softwareversion: 8.2.0

Software version 1: --

Software version 2: --

Supplier: Temic

Hardware vare nummer: Simulation

Software part number (customer): 1669021401

Software part number (code): --

Software part number (data): --

Serie nummer: --

Fejlkoder

Controls

Clear DTC

Levende Data

Position of power window: 1432

Power window up switch: Ikke aktiv

Power window down switch: Ikke aktiv

Power window normalizing: Denormalized

Power window blockage: Ikke registreret

Power window motor overtemperature: Ikke registreret

Roller sun blind position: 2392

Roller sun blind closed: Nej

Roller sun blind open: Nej

Roller sun blind downwards: Ikke aktiv

Roller sun blind upwards: Ikke aktiv

Roller sun blind motor is blocked: Ikke registreret

Central locking switch (unlock): Ikke aktiveret

Central locking switch (lock): Ikke aktiveret

Rotary tumbler: Not actuated

Prelatch door lock microswitch: Not actuated

Actuator motor for power closing switches: Lukket

External operation of door handle: Not actuated

Internal operation of door handle: Not actuated

Right rear power window switch: Not actuated

Left rear power window switch: Not actuated

Roller sun blind for rear panoramic sliding sunroof: Not actuated

Switches Roller sun blind for rear window: Not actuated

Door handle illumination: Sluk

Exit and warning lamp: Sluk

Switch illumination adjustment control: Sluk

Illumination brightness control: 120 %

LED 'Seat heater': Sluk

Udgangs test

Controls

Central locking

Elruder

Denormalization power window

Roller sun blind

Exit and warning lamp

Door handle illumination

LED 'Seat heater'

Switch and controls illumination

Muligheder

Controls

Normalization power window

Deactivation of production mode

ECU Reset

Konfiguration

Controls

CCL comfort actuation

Parameterization of lights

Bandendeprogrammierung DAG

BSM parameter