PKW, MERCEDES, GLE 167, 167.189 Mercedes-AMG GLE 63 S 4MATIC+, Left rear door (DCU-LR)

Türsteuergerät - Left rear door (DCU-LR) - 0

Identifikation

Diagnoseversion: 02 04 07

Boot software number: 10.32.0

Hardware-Version: 8.2.0

Softwareversion: 8.2.0

Software version 1: --

Software version 2: --

Lieferant: Temic

Hardware-Teilenummer: Simulation

Software part number (customer): 1669021401

Software part number (code): --

Software part number (data): --

Seriennummer: --

Fehlercode

Controls

Fehlercode löschen

Ist-Werte

Position of power window: 1432

Power window up switch: Nicht aktiv

Power window down switch: Nicht aktiv

Power window normalizing: Denormalized

Power window blockage: Nicht erkannt

Power window motor overtemperature: Nicht erkannt

Roller sun blind position: 2392

Roller sun blind closed: Nein

Roller sun blind open: Nein

Roller sun blind downwards: Nicht aktiv

Roller sun blind upwards: Nicht aktiv

Roller sun blind motor is blocked: Nicht erkannt

Central locking switch (unlock): Nicht aktiviert

Central locking switch (lock): Nicht aktiviert

Rotary tumbler: Not actuated

Prelatch door lock microswitch: Not actuated

Actuator motor for power closing switches: Geschlossen

External operation of door handle: Not actuated

Internal operation of door handle: Not actuated

Right rear power window switch: Not actuated

Left rear power window switch: Not actuated

Roller sun blind for rear panoramic sliding sunroof: Not actuated

Switches Roller sun blind for rear window: Not actuated

Door handle illumination: AUS

Exit and warning lamp: AUS

Switch illumination adjustment control: AUS

Illumination brightness control: 120 %

LED 'Seat heater': AUS

Stellgliedtest

Controls

Central locking

Fensterheber

Denormalization power window

Roller sun blind

Exit and warning lamp

Door handle illumination

LED "Sitzheizung"

Switch and controls illumination

Dienst­programme

Controls

Normalization power window

Deactivation of production mode

ECU Reset

Konfiguration

Controls

CCL comfort actuation

Parameterization of lights

Bandendeprogrammierung DAG

BSM parameter