Bil, MERCEDES, GLC 253, 253.993 GLC F-CELL Off-Roader, Power electronics (SG-EM)
Strøm kilde kontrol - Power electronics (SG-EM) - 0
Identifikation
Diagnose version: 00 03 17
Boot software number: 0.0.0
Hardwareversion: 0.0.0
Softwareversion: --
Software version 1: --
Software version 2: --
Supplier: --
Hardware vare nummer:
Software part number (customer): --
Software part number (code): --
Software part number (data): --
Serie nummer: --
Fejlkoder
P010000: Mass or volume air flow (MAF) sensor 1/A - electrical fault
Controls
Clear DTC
Levende Data
Seat height adjustment current position: 0.00 V
Seat fore/aft adjustment current position: 0.00 V
Circuit 30C power supply: FALSK
System state: Standby
Mode: Tomgang
Ignition status: Ignition key removed and ignition lock locked
Gaspedalposition: -- %
Belastning Motor: -- %
Engine run status: Stop
Gear: N
12V faulty: FALSK
15V faulty: FALSK
1.5V ASIC faulty: FALSK
3.3V faulty: FALSK
5V faulty: FALSK
5VRef faulty: FALSK
Boost faulty: FALSK
Backup faulty: FALSK
Udgangs test
Controls
Power stage
Power stage production
Konfiguration
Controls
Redigere konfiguration