Bil, MERCEDES, GL 164, 164.871 GL 450 4MATIC, Stationary heater (STH)

Klima Anlæg - Stationary heater (STH) - 0

Identifikation

MB number for hardware: 2218705187

Diagnose version: 2.1

Hardware number: 06.27

Software nummer: 06.43

Supplier: Temic

Diagnose version: 02 01

Fejlkoder

9053: Flame has gone out more than 4 times during the heating cycle

Controls

Clear DTC

Levende Data

Supply voltage: 10 V

Water temperature: 101 °C

CO2 setting of combustion air blower: 129

Stationary heater in heating mode: Aktiv

Stationary heater in ventilation mode: Aktiv

STH heater unit: Aktiv

Operating state: Part load

STH switchover valve: Aktiv

STH switchover valve on/off ratio: 96

Combustion air blower: Aktiv

Off signal to telestart receiver: Aktiv

Fuel preheating system: Aktiv

Fuel preheating system on/off ratio: 23

Flame monitor glowpin unit: Aktiv

Flame monitor glowpin unit on/off ratio: 85

Flame monitor glowpin unit has flame detected: Ja

Auxiliary heater metering pump: Aktiv

Auxiliary heater metering pump period: 1.170 sek

On signal to telestart receiver: Aktiv

STH switch: betjenes

Number of teach-in processes in STH radio remote control receiver: 11

On signal from the telestart receiver: Ja

Off signal from the telestart receiver: Ja