PKW, MERCEDES, G 463, 463.306 G 350 BlueTEC, Selective catalytic reduction (SCR)
Motor - Selective catalytic reduction (SCR) - 0
Identifikation
Diagnoseversion: 00 17 21
Boot software number: 33.1.2
Hardware-Version: 8.2.0
Softwareversion: 8.2.0
Software version 1: --
Software version 2: --
Lieferant: Bosch
Hardware-Teilenummer: 2048203226
Software part number (customer): 0104482140
Software part number (code): --
Software part number (data): --
Seriennummer: --
FIN: WDC1660041Z000815
VIN stored: WD3PE8CCXF5952658
Fehlercode
000100: Ignore fault code if it nevertheless occurs
20B811: Output for heating element of AdBlue delivery module - circuit short to battery
20BD13: Output for heating element 'AdBlue tank' electrical fault or circuit open
Controls
Fehlercode löschen
Ist-Werte
Exhaust temperature upstream of SCR catalytic converter: -0 °C
Pressure in AdBlue delivery pump: 0 hPa
Status of AdBlue tank fill level sensor EMPTY: 0.0
Status of AdBlue tank fill level sensor RESERVE: 0.0
Status of AdBlue tank fill level sensor FULL: 8200.0
Heating of AdBlue tank module: 0 mA
Heater of AdBlue line: 0 mA
Heating of AdBlue delivery module: 0 mA
Temperature in AdBlue tank: 30 °C
Pressure in AdBlue delivery pump: 0 hPa
Tankfüllstand: 31 L
Tankfüllstand: 100.00 %
Temperature in AdBlue tank: -5302 mV
AdBlue fill level sensor 1 (raw value): 896 mV
AdBlue fill level sensor 2 (raw value): -6134 mV
AdBlue fill level sensor 3 (raw value): -6130 mV
Fill level of AdBlue tank: Leer
Motorstart: A3
Heating of AdBlue pressure line: Actuated
Heating of AdBlue tank module: Actuated
Heating of AdBlue delivery module: Not actuated
System status of control unit SCR: Druckminderung
AdBlue reversing valve: Switching of reversing valve in direction 'AdBlue metering valve'
Batteriespannung: 8.040 V
Geber für Fahrgeschwindigkeit: 0 km/h
Tatsächlicher Lambdawert: 0
Geber für Außentemperatur: 177 °C
Luftdrucksensor: 4498 hPa
Motordrehzahl: 500 UpM
Pressure in AdBlue delivery pump: -54.60 %
Fill quantity in AdBlue pressure line: 93 %
AdBlue metering valve: 100 %
Connector AdBlue metering valve: Angeschlossen
Warning lamp 'AdBlue': AUS
Stellgliedtest
Controls
Heating of AdBlue tank module
Heating of AdBlue pressure line
Heating of AdBlue delivery module
AdBlue reversing valve
AdBlue delivery pump
AdBlue return
Dienstprogramme
Controls
Display consumption
Resetting calculated fill level of AdBlue tank