Car, MERCEDES, E 212, 212.026 E 350 BlueTEC Sedan , E 350 d Sedan, Selective catalytic reduction (SCR)

Engine - Selective catalytic reduction (SCR) - 0

Identification

Diagnostic version: 00 17 21

Boot software number: 33.1.2

Hardware version: 8.2.0

Software version: 8.2.0

Software version 1: --

Software version 2: --

Supplier: Bosch

Hardware part number: 2048203226

Software part number (customer): 0104482140

Software part number (code): --

Software part number (data): --

Serial number: --

VIN no: WDC1660041Z000815

VIN stored: WD3PE8CCXF5952658

DTC

000100: Ignore fault code if it nevertheless occurs

20B811: Output for heating element of AdBlue delivery module - circuit short to battery

20BD13: Output for heating element 'AdBlue tank' electrical fault or circuit open

Controls

Clear DTC

Data stream

Exhaust temperature upstream of SCR catalytic converter: 727 °C

Pressure in AdBlue delivery pump: 200 hPa

Status of AdBlue tank fill level sensor EMPTY: 9999.0

Status of AdBlue tank fill level sensor RESERVE: 9999.0

Status of AdBlue tank fill level sensor FULL: 9999.0

Heating of AdBlue tank module: 1000 mA

Heater of AdBlue line: 1000 mA

Heating of AdBlue delivery module: 1000 mA

Temperature in AdBlue tank: 741 °C

Pressure in AdBlue delivery pump: 10066 hPa

Fuel tank level: 31 L

Fuel tank level: 100.00 %

Temperature in AdBlue tank: -5302 mV

AdBlue fill level sensor 1 (raw value): 896 mV

AdBlue fill level sensor 2 (raw value): -6134 mV

AdBlue fill level sensor 3 (raw value): -6130 mV

Fill level of AdBlue tank: Empty

Engine start: A3

Heating of AdBlue pressure line: Actuated

Heating of AdBlue tank module: Actuated

Heating of AdBlue delivery module: Not actuated

System status of control unit SCR: Pressure reduction

AdBlue reversing valve: Switching of reversing valve in direction 'AdBlue metering valve'

Battery voltage: 8.040 V

Vehicle speed sensor: 0 km/h

Actual lambda value: 0

Ambient temperature sensor: 177 °C

Barometric pressure sensor: 4498 hPa

Engine speed: 500 rpm

Pressure in AdBlue delivery pump: -54.60 %

Fill quantity in AdBlue pressure line: 93 %

AdBlue metering valve: 100 %

Connector AdBlue metering valve: Connected

Warning lamp 'AdBlue': Off

Actuators test

Controls

Heating of AdBlue tank module

Heating of AdBlue pressure line

Heating of AdBlue delivery module

AdBlue reversing valve

AdBlue delivery pump

AdBlue return

Utility

Controls

Display consumption

Resetting calculated fill level of AdBlue tank