PKW, MERCEDES, E 211, 211.283 E 500 4MATIC, 2005-2006, Stationary heater (STH)

Klimaregelung - Stationary heater (STH) - 0

Identifikation

Herstellungsdatum: 06 10 11

Hardwarenummer: 01.06

Softwarenummer: 10.06

Diagnoseversion: 4.1

MB Hardwarenummer: 16 95 45 19 08

Lieferant: Kostal

Identifikator: 04 01

Fehlercode

9814: Crash interlock has been activated

Event 9805: On-board electrical system voltage was below the set undervoltage shutoff threshold for 20 s

Controls

Fehlercode löschen

Ist-Werte

Versorgungsspannung: 10 V

Kühlmitteltemperatur: 73 °C

Power factor of combustion air blower: 41 %

On-off ratio of the glow element: 231 %

Period of metering pump: 560 ms

Vehicle power supply emergency mode is taken into account: Ja

Undervoltage shutoff threshold: 16 min

Heizperiode: 2550 min

Reduction factor of ventilation duration to heating duration: Belüftungsdauer = Heizdauer

Correction factor of combustion air blower: 31

Stationary heater in heating mode: Nein

Stationary heater in ventilation mode: Nein

Stationary heater active: Nein

STH switchover valve: AUS

Verbrennungsluftgebläse: AUS

Flame monitor glowpin unit: AUS

Flame sensor - flame detection: Flame detected

STH fuel metering pump: AUS

Signals from remote control receiver: Switch on and switch off switch signal not available

Telestart receiver: number of learned transmitters: 0

Number of teach-in processes in STH radio remote control receiver: 5

Kanal: Channel 11

System test status: In Ordnung