Bil, MERCEDES, E 211, 211.016 E 270 CDI, 2005-2006, Stationary heater (STH)

Klima Anlæg - Stationary heater (STH) - 0

Identifikation

Production date: 06 10 11

Hardware number: 01.06

Software nummer: 10.06

Diagnose version: 4.1

MB number for hardware: 16 95 45 19 08

Supplier: Kostal

Identificere : 04 01

Fejlkoder

9814: Crash interlock has been activated

Event 9805: On-board electrical system voltage was below the set undervoltage shutoff threshold for 20 s

Controls

Clear DTC

Levende Data

Supply voltage: 10 V

Kølemiddeltemperatur: 73 °C

Power factor of combustion air blower: 41 %

On-off ratio of the glow element: 231 %

Period of metering pump: 560 ms

Vehicle power supply emergency mode is taken into account: Ja

Undervoltage shutoff threshold: 16 min

Heating period: 2550 min

Reduction factor of ventilation duration to heating duration: Ventilation duration = heating duration

Correction factor of combustion air blower: 31

Stationary heater in heating mode: Nej

Stationary heater in ventilation mode: Nej

Stationary heater active: Nej

STH switchover valve: Sluk

Combustion air blower: Sluk

Flame monitor glowpin unit: Sluk

Flame sensor - flame detection: Flame detected

STH fuel metering pump: Sluk

Signals from remote control receiver: Switch on and switch off switch signal not available

Telestart receiver: number of learned transmitters: 0

Number of teach-in processes in STH radio remote control receiver: 5

Channel: Channel 11

System test status: OK