Bil, MERCEDES, E 211, 211.090 E 500 4MATIC, Adaptive brake (ABR)

Bremse system - Adaptive brake (ABR) - 0

Identifikation

MB number for hardware: 0375452932

Diagnose version: 0.3

Hardware number: 06.42

Software nummer: 06.42

Supplier: Bosch

Diagnose version: 00 03

Fejlkoder

7394: CAN-bus off

441A: Left front wheel speed sensor test wiring/plug connection

7266: DTR distronic: consequential fault

7271: DTR: test wheel speed signals (Front axle)

Controls

Clear DTC

Levende Data

Solenoid valves: 12 V

Solenoid valves (Internal value): 13 V

Sideacceleration: 17 m/s²

Rotational speed: 47 °/sec

Ratvinkelføler: 39 °

Bremsetrykføler: 6 bar

Left front pressure sensor: 32 bar

Left rear pressure sensor: 10 bar

Stop light switch normally open contact: Sluk

Stop light switch normally closed contact: Sluk

Parking brake indicator switch: Sluk

ESP OFF switch: Sluk

Actual gear: 3

Target gear: 7

CAN data: FCOD_BR: BR211

CAN data: FCOD_KAR: C - Coupe

CAN data: FCOD_MOT: M272 E35

CAN data: accelerator pedal position: 58 %

Vehicle speed left front axle: 103 km/h

Left front wheel rotation direction: Frem

Left front gap wheel speed: OK

Vehicle speed right front axle: 208 km/h

Right front wheel rotation direction: Frem

Right front gap wheel speed: Ugyldig

Vehicle speed left rear axle: 219 km/h

Left rear wheel rotation direction: Frem

Left rear gap wheel speed: Ikke Ok

Vehicle speed right rear axle: 176 km/h

Right rear wheel rotation direction: Frem

Right rear gap wheel speed: OK

Kilometer reading at warning no. 1: 75014 km

Kilometer reading at warning no. 2: 101482 km

Kilometer reading at warning no. 3: 86798 km

Kilometer reading at reactivation no. 1: 110188 km

Kilometer reading at reactivation no. 2: 78416 km

Kilometer reading at reactivation no. 3: 4720 km

Activation no. 1: Manuelt

Activation no. 2: Automatisk

Activation no. 3: Automatisk

Status 'Tire pressure loss warner': Not present / Not coded

Fartpilotkontakt: Set-Accelerate

Speedtronic active: Nej

SPS solenoid valve: 37507 mA

Udgangs test

Controls

PML speed-sensitive power steering