Bil, MERCEDES, E 207, 207.457 E 350 CGI BlueEFFICIENCY Cabriolet, Battery management system (BMS)

Strøm kilde kontrol - Battery management system (BMS) - 0

Identifikation

Diagnose version: 00 10 03

Boot software number: 0.0.0

Hardwareversion: 0.0.0

Softwareversion: --

Software version 1: --

Software version 2: --

Supplier: --

Hardware vare nummer:

Software part number (customer):

Software part number (code): --

Software part number (data): --

Serie nummer: --

Stel nr.:

VIN stored:

Fejlkoder

P010000: Mass or volume air flow (MAF) sensor 1/A - electrical fault

Controls

Clear DTC

Levende Data

Status: Ikke aktiv

Ignition status: Ignition key removed and ignition lock locked

Request of contactor: Ikke aktiv

Limp home: Ikke aktiv

Switch close request: Ikke aktiv

Analog crash signal from airbag: Ikke aktiv

Crash X signal via CAN: Ikke aktiv

PNHV_ChrgCurr_Max_BMS: -- A

PNHV_DschrgCurr_Max_BMS: -- A

Refrigerant temperature: 0.0 °C

Temperature sensor A: 0.0 °C

Temperature sensor B: 0.0 °C

Temperature sensor C: 0.0 °C

Temperature sensor D: 0.0 °C

Interlock generator: Ikke aktiv

Interlock circuit error: Nej

High-voltage battery current value: 0.0 A

Max: 0.00 %

Min: 0.00 %

High-voltage battery charge level: 0.00 %

High-voltage battery charge level: 0.00 %

Battery cell voltage 1: 0.00 V

Battery cell voltage 2: 0.00 V

Battery cell voltage 3: 0.00 V

Battery cell voltage 4: 0.00 V

Battery cell voltage 5: 0.00 V

Battery cell voltage 6: 0.00 V

Battery cell voltage 7: 0.00 V

Battery cell voltage 8: 0.00 V

Battery cell voltage 9: 0.00 V

Battery cell voltage 10: 0.00 V

Battery cell voltage 11: 0.00 V

Battery cell voltage 12: 0.00 V

Battery cell voltage 13: 0.00 V

Battery cell voltage 14: 0.00 V

Battery cell voltage 15: 0.00 V

Battery cell voltage 16: 0.00 V

Battery cell voltage 17: 0.00 V

Battery cell voltage 18: 0.00 V

Battery cell voltage 19: 0.00 V

Battery cell voltage 20: 0.00 V

Battery cell voltage 21: 0.00 V

Battery cell voltage 22: 0.00 V

Battery cell voltage 23: 0.00 V

Battery cell voltage 24: 0.00 V

Battery cell voltage 25: 0.00 V

Battery cell voltage 26: 0.00 V

Battery cell voltage 27: 0.00 V

Battery cell voltage 28: 0.00 V

Battery cell voltage 29: 0.00 V

Battery cell voltage 30: 0.00 V

Battery cell voltage 31: 0.00 V

Battery cell voltage 32: 0.00 V

Battery cell voltage 33: 0.00 V

Battery cell voltage 34: 0.00 V

Battery cell voltage 35: 0.00 V

Average cell voltage: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

PNHV_SupBatCutSW_Stat: Åben

PNHV_SupBat_CoolValveStat: Åben

Insulation resistance: 0.00 kOhm

Iso info: Ikke aktiv

Iso warning: Ikke aktiv

Iso alarm: Ikke aktiv

Isolation Voltage Plus: 0.0 V

Isolation Voltage Minus: 0.0 V

Iso fault location: No fault

Udgangs test

Controls

Control contactor

Coolant shut-off valve

Interlock generator