Bil, MERCEDES, CLS 219, 219.372 CLS 500, CLS 550, 2006-, Automatic air conditioning (AAC)

Klima Anlæg - Automatic air conditioning (AAC) - 0

Identifikation

Production date: 06 10 11

Hardware number: 01.06

Software nummer: 10.06

Diagnose version: 4.7

MB number for hardware: 16 95 45 19 08

Supplier: Kostal

Identificere : 04 07

Fejlkoder

9350: Communication error of AC bus with C-AAC multifunction sensor

9465: Blower regulator overload shutdown

9460: Communication error of AC bus with right air mix flap motor

Controls

Clear DTC

Levende Data

Evaporator temperature sensor: -99 °C

OCP: N70b1 (in-car temperature sensor): 22 °C

In-car temperature sensor: -99 °C

Ambient temperature sensor: 31 °C

Refrigerant pressure: 18 bar

Motor Hastighed: 751

Request to A/C compressor: 0 %

A/C compressor torque: 0 N·m

A/C compressor current consumption: 0 mA

Motor kølevæske temperatur føler: 255 °C

Left front sun sensor light intensity: 0 %

Right front sun sensor light intensity: 0 %

Left rear sun sensor light intensity: 0 %

Right rear sun sensor light intensity: 0 %

C-AAC sun sensor (4 in total) total light intensity: 0 %

Terminal 58d: 0 %

Køretøjets hastighed sensor: 0 km/h

Target left air mix flap motor position: 20534

Left air mix flap motor position: -9997

Stored left air mix flap adjustment motor travel: 1913

Current left air mix flap adjustment motor travel: 1915

Lost communication between AAC pushbutton control module and left air mix flap motor: Ja

Left air mix flap motor electrical fault: Nej

Left air mix flap motor mechanical fault: Ja

Left air mix flap motor excess temperature: Nej

Left air mix flap motor position motors alignment: OK

Target right air mix flap actuator motor position: -9923

Right air mix flap actuator motor position: -9817

Stored right air mix flap adjustment motor travel: 1956

Current right air mix flap adjustment motor travel: 1907

Lost communication between AAC pushbutton control module and right air mix flap motor: Ja

Right air mix flap motor electrical fault: Nej

Right air mix flap motor mechanical fault: Ja

Right air mix flap motor excess temperature: Nej

Right air mix flap motor position motors aligment: OK

Target left defroster flap motor position: -7624

Left defroster flap actuator motor position: 12965

Stored left defroster flap adjustment motor travel: 31541

Current left defroster flap adjustment motor travel: 45351

Lost communication between AAC pushbutton control module and left defroster flap motor: Nej

Left defroster flap actuator electrical fault: Ja

Left defroster flap motor mechanical fault: Nej

Left defroster flap actuator excess temperature: Ja

Left defroster flap actuator position motors aligment: OK

Target right defroster flap motor position: 24919

Right defroster flap motor position: 12572

Stored right defroster flap adjustment motor travel: 49252

Current right defroster flap adjustment motor travel: 37175

Lost communication between AAC pushbutton control module and right defroster flap motor: Ja

Right defroster flap actuator electrical fault: Nej

Right defroster flap motor mechanical fault: Ja

Right defroster flap actuator excess temperature: Nej

Right defroster flap actuator position motors alignment: OK

Target right footwell flap motor position: 24883

Right footwell flap motor position: 36229

Stored right footwell flap adjustment motor travel: 49705

Current right footwell flap adjustment motor travel: 41512

Lost communication between AAC pushbutton control module and right footwell flap motor: Ja

Right footwell flap motor electrical fault: Nej

Right footwell flap motor mechanical fault: Ja

Right footwell flap motor excess temperature: Nej

Right footwell flap motor position motor alignment: OK

Target left footwell flap actuator motor position: 23138

Left footwell flap motor position: -3817

Stored left footwell flap adjustment motor travel: -7929

Current left footwell flap adjustment motor travel: 2142

Lost communication between AAC pushbutton control module and left footwell flap motor: Ja

Left footwell flap actuator electrical fault: Nej

Left footwell flap motor mechanical fault: Ja

Left footwell flap actuator excess temperature: Nej

Left footwell flap actuator position motor alignment: OK

Target right center ventilation air flap motor position: 296

Right center ventilation air flap motor position: -3454

Stored right center ventilation air flap adjustment motor travel: 49704

Current right center ventilation air flap adjustment motor travel: 42340

Lost communication between AAC pushbutton control module and right center ventilation air flap motor: Ja

Right center ventilation air flap motor electrical fault: Nej

Right center ventilation air flap motor mechanical fault: Ja

Right center ventilation air flap motor excess temperature: Nej

Right center ventilation air flap motor position motor alignment: OK

Target left center ventilation air flap motor position: 29256

Left center ventilation air flap actuator motor position: 20534

Stored left center ventilation air flap adjustment motor travel: 29208

Current left center ventilation air flap adjustment motor travel: 2726

Lost communication between AAC pushbutton control module and left center ventilation air flap motor: Ja

Left center ventilation air flap motor electrical fault: Nej

Left center ventilation air flap motor mechanical fault: Ja

Left center ventilation air flap motor excess temperature: Nej

Left center ventilation air flap motor position motor alignment: OK

Target value of fresh/recirculation air flap motor: -9997

Fresh/recirculation air flap motor: 15172

Stored fresh and recirculated air flaps adjustment motor travel: 2114

Current fresh and recirculated air flaps adjustment motor travel: 2119

Lost communication between AAC pushbutton control module and fresh and recirculated air flaps motor: Ja

Fresh and recirculation air flaps motor electrical fault: Nej

Fresh and recirculation air flaps motor mechanical fault: Ja

Fresh and recirculation air flaps motor excess temperature: Nej

Fresh and recirculation air flaps motor position motor alignment: OK

Target left rear air mix flap motor position: 45075

Left rear air mix flap motor position: 49447

Stored left rear air mix flap adjustment motor travel: 46691

Current left rear air mix flap adjustment motor travel: 49879

Lost communication between AAC pushbutton control module and left rear air mix flap motor: Ja

Left rear air mix flap motor electrical fault: Nej

Left rear air mix flap motor mechanical fault: Ja

Left rear air mix flap motor excess temperature: Nej

Left rear air mix flap motor position motor alignment: OK

Target right rear air mix flap motor position: 45075

Right rear air mix flap motor position: 52070

Stored right rear air mix flap adjustment motor travel: 41730

Current right rear air mix flap adjustment motor travel: 8501

Lost communication between AAC pushbutton control module and right rear air mix flap motor: Ja

Right rear air mix flap motor electrical fault: Nej

Right rear air mix flap motor mechanical fault: Ja

Right rear air mix flap motor excess temperature: Nej

Right rear air mix flap motor position motor alignment: OK

Target value of blower regurator for requirement of blower capacity: 18 %

Blower motor current consumption: 1.6 A

Blower regulator temperature: 1.0 °C

Blower regulator supply voltage: 12.0 V

Multifunction sensor CO value: 530

Multifunction sensor NOx value: 354

Multifunction sensor dewpoint temperature: 13 °C

Multifunction sensor relative air humidity: 41

Multifunction sensor current ambient temperature: 58 °C

Power supply: 12 V

Left heating capacity: 100 %

Right heating capacity: 100 %

DF signal (Analog): 0 %

Cutoff because of overvoltage at terminal 30: Nej

Cutoff because of undervoltage at terminal 30: Nej

Shutdown due to excessive temperature: Nej

Generator output: OK

PTC heater booster: OK

PTC heater booster: 0 A

Heating element 1: short circuit: Ikke tilstede

Heating element 2: short circuit: Ikke tilstede

Heating element 3: short circuit: Ikke tilstede

Heating element 4: short circuit: Ikke tilstede

Heating element 5: short circuit: Ikke tilstede

Heating element 6: short circuit: Ikke tilstede

Heating element 7: short circuit: Ikke tilstede

Heating element 8: short circuit: Ikke tilstede

Heating element 1: open circuit: Ikke tilstede

Heating element 2: open circuit: Ikke tilstede

Heating element 3: open circuit: Ikke tilstede

Heating element 4: open circuit: Ikke tilstede

Heating element 5: open circuit: Ikke tilstede

Heating element 6: open circuit: Ikke tilstede

Heating element 7: open circuit: Ikke tilstede

Heating element 8: open circuit: Ikke tilstede

Udgangs test

Controls

Heater booster

Left defroster flap motor

Right defroster flap motor

Left footwell flap motor

Right footwell flap motor

Left center ventilation air flap actuator motor, Left air mix flap motor

Right center ventilation air flap actuator motor, Right air mix flap motor

Left rear air mix flap motor

Right rear air mix flap motor

Left and right defroster flaps motor

Left and right footwell flaps motor

Center ventilation flap motor

Left and right air mix flaps motor

Fresh and recirculation air flaps motor

Activated charcoal filter flap adjustment motor

Blæsermotor

Engine/AC electric suction fan

Illumination

Display test images on the LCD display

Check of LEDs

A/C compressor relay

Blower of interior temperature sensor

Heat exchanger shutoff motor

Closing air recirculation flap (for cleaning)