Bil, MERCEDES, CLS 218, 218.367 CLS 400 4MATIC Coupe, Selective catalytic reduction (SCR)

Motor - Selective catalytic reduction (SCR) - 0

Identifikation

Diagnose version: 00 17 21

Boot software number: 33.1.2

Hardwareversion: 8.2.0

Softwareversion: 8.2.0

Software version 1: --

Software version 2: --

Supplier: Bosch

Hardware vare nummer: 2048203226

Software part number (customer): 0104482140

Software part number (code): --

Software part number (data): --

Serie nummer: --

Stel nr.: WDC1660041Z000815

VIN stored: WD3PE8CCXF5952658

Fejlkoder

000100: Ignore fault code if it nevertheless occurs

20B811: Output for heating element of AdBlue delivery module - circuit short to battery

20BD13: Output for heating element 'AdBlue tank' electrical fault or circuit open

Controls

Clear DTC

Levende Data

Exhaust temperature upstream of SCR catalytic converter: 727 °C

Pressure in AdBlue delivery pump: 200 hPa

Status of AdBlue tank fill level sensor EMPTY: 9999.0

Status of AdBlue tank fill level sensor RESERVE: 9999.0

Status of AdBlue tank fill level sensor FULL: 9999.0

Heating of AdBlue tank module: 1000 mA

Heater of AdBlue line: 1000 mA

Heating of AdBlue delivery module: 1000 mA

Temperature in AdBlue tank: 741 °C

Pressure in AdBlue delivery pump: 10066 hPa

Fuel tank level: 31 L

Fuel tank level: 100.00 %

Temperature in AdBlue tank: -5302 mV

AdBlue fill level sensor 1 (raw value): 896 mV

AdBlue fill level sensor 2 (raw value): -6134 mV

AdBlue fill level sensor 3 (raw value): -6130 mV

Fill level of AdBlue tank: Tom

Engine start: A3

Heating of AdBlue pressure line: Actuated

Heating of AdBlue tank module: Actuated

Heating of AdBlue delivery module: Not actuated

System status of control unit SCR: Pressure reduction

AdBlue reversing valve: Switching of reversing valve in direction 'AdBlue metering valve'

Batteri spænding: 8.040 V

Køretøjets hastighed sensor: 0 km/h

Actual lambda value: 0

Ambient temperature sensor: 177 °C

Barometrisk tryk føler: 4498 hPa

Motor Hastighed: 500 Omdr.

Pressure in AdBlue delivery pump: -54.60 %

Fill quantity in AdBlue pressure line: 93 %

AdBlue metering valve: 100 %

Connector AdBlue metering valve: Tilsluttet

Warning lamp 'AdBlue': Sluk

Udgangs test

Controls

Heating of AdBlue tank module

Heating of AdBlue pressure line

Heating of AdBlue delivery module

AdBlue reversing valve

AdBlue delivery pump

AdBlue return

Muligheder

Controls

Display consumption

Resetting calculated fill level of AdBlue tank