Car, MERCEDES, CL 215, 215.374 CL 55 Compressor AMG, Stationary heater (STH)
Climate control - Stationary heater (STH) - 0
Identification
Production date: 02 11 20
Hardware number: 32.00
Software number: 36.02
Diagnostic version: 3.0
MB number for hardware: 22 05 40 25 45
Supplier: VDO
Identifier: 03 00
DTC
9773: Locked or uncoded control unit is installed
Controls
Clear DTC
Data stream
Power supply: 12 V
Coolant temperature: 88 °C
Power factor of combustion air blower: 127 %
On-off ratio of the glow element: 128 %
Period of metering pump: 1290 ms
Undervoltage shutoff threshold: 12 V
Heating period: 50 min
Reduction factor of ventilation duration to heating duration: Ventilation duration = heating duration
CO2 setting of combustion air blower: -159
Correction factor of combustion air blower: -33
Stationary heater in heating mode: No
Stationary heater in ventilation mode: No
Stationary heater active: No
Circulation pump: Off
Combustion air blower: Off
Glow pin unit flam monitor: Off
Flame sensor - flame detection: No flame detected
STH fuel metering pump: Off
Signals from remote control receiver: Switch on and switch off switch signal available
Telestart receiver: number of learned transmitters: 1
Actuators test
Controls
Switch on stationary heater (normal mode)
Switch on stationary heater (test mode)
Heating/Switch on ventilation in line with request from AC pushbutton control module
Switch on Glow pin unit flam monitor
Switch on Circulation pump
Switch on Combustion air blower
Switch on STH fuel metering pump
Configuration
Controls
Edit configuration