Bil, MERCEDES, C 203, 203.752 C 230, Stationary heater (STH)
Klima Anlæg - Stationary heater (STH) - 0
Identifikation
Production date: 06 10 11
Hardware number: 01.06
Software nummer: 10.06
Diagnose version: 4.1
MB number for hardware: 16 95 45 19 08
Supplier: Kostal
Identificere : 04 01
Fejlkoder
9814: Crash interlock has been activated
Event 9805: On-board electrical system voltage was below the set undervoltage shutoff threshold for 20 s
Controls
Clear DTC
Levende Data
Supply voltage: 10 V
Kølemiddeltemperatur: 73 °C
Power factor of combustion air blower: 41 %
On-off ratio of the glow element: 231 %
Period of metering pump: 560 ms
Vehicle power supply emergency mode is taken into account: Ja
Undervoltage shutoff threshold: 16 min
Heating period: 2550 min
Reduction factor of ventilation duration to heating duration: Ventilation duration = heating duration
Correction factor of combustion air blower: 31
Stationary heater in heating mode: Nej
Stationary heater in ventilation mode: Nej
Stationary heater active: Nej
STH switchover valve: Sluk
Combustion air blower: Sluk
Flame monitor glowpin unit: Sluk
Flame sensor - flame detection: Flame detected
STH fuel metering pump: Sluk
Signals from remote control receiver: Switch on and switch off switch signal not available
Telestart receiver: number of learned transmitters: 0
Number of teach-in processes in STH radio remote control receiver: 5
Channel: Channel 11
System test status: OK