PKW, MERCEDES, C 203, 203.218 C 30 CDI AMG, 2003-2007, Stationary heater (STH)
Klimaregelung - Stationary heater (STH) - 0
Identifikation
Herstellungsdatum: 06 10 11
Hardwarenummer: 01.06
Softwarenummer: 10.06
Diagnoseversion: 4.1
MB Hardwarenummer: 16 95 45 19 08
Lieferant: Kostal
Identifikator: 04 01
Fehlercode
9814: Crash interlock has been activated
Event 9805: On-board electrical system voltage was below the set undervoltage shutoff threshold for 20 s
Controls
Fehlercode löschen
Ist-Werte
Versorgungsspannung: 10 V
Kühlmitteltemperatur: 73 °C
Power factor of combustion air blower: 41 %
On-off ratio of the glow element: 231 %
Period of metering pump: 560 ms
Vehicle power supply emergency mode is taken into account: Ja
Undervoltage shutoff threshold: 16 min
Heizperiode: 2550 min
Reduction factor of ventilation duration to heating duration: Belüftungsdauer = Heizdauer
Correction factor of combustion air blower: 31
Stationary heater in heating mode: Nein
Stationary heater in ventilation mode: Nein
Stationary heater active: Nein
STH switchover valve: AUS
Verbrennungsluftgebläse: AUS
Flame monitor glowpin unit: AUS
Flame sensor - flame detection: Flame detected
STH fuel metering pump: AUS
Signals from remote control receiver: Switch on and switch off switch signal not available
Telestart receiver: number of learned transmitters: 0
Number of teach-in processes in STH radio remote control receiver: 5
Kanal: Channel 11
System test status: In Ordnung