Bil, CHERY, ARRIZO 8 (M1E), Klima Anlæg (CLM)

Klima Anlæg - Klima Anlæg (CLM) - 0

Identifikation

Vehicle manufacturer ECU software number: 01.11.00

Vehicle manufacturer ECU hardware number: 0.3.0

Vehicle manufacturer spare part number: 301000278AA

Systemidentifikation: 9AK

ECU serial number: --

Logistics software part number: --

Boot software number: FBL-V1.3.1

Calibration version: --

Logistics software part number: --

System supplier ECU calibration data version number: --

System supplier ECU calibration data part number: --

Fremstillings dato: --

Stel nr.: --

Active diagnostic session: --

System name: --

System supplier ECU software version number: --

Logistics hardware part number: --

Logistics assembly part number: --

Fingerprint 1 complement value: --

Fingerprint 2 complement value: --

System supplier ECU hardware number: --

Repair shop code or tester serial number: --

System supplier ECU calibration data version number: --

Programming date: --

Application ID: --

Fejlkoder

Controls

Clear DTC

Levende Data

Internal temperature (left): -3.50 °C

Ambient temperature: -3.50 °C

Evaporator temperature: -4.00 °C

Solar sensor element left: 365 W/m2

Blower voltage: 12.50 V

Recycling motor control: 73 %

Internal temperature (right): -3.50 °C

Solar sensor element right: 345 W/m2

Batteri spænding: 12.50 V

AQS sensor PWM duty: 73 %

AQS sensor PWM period: 464.10 Hz

Blower fan output: 72 %

Fragrance motor step: 73 %

ECV PWM duty: 73 %

ECV positive feedback current: 4641 mA

ECV negative feedback current: 8532 mA

A/C compressor torque: 7.20 N·m

ECV negative control: forbeholdt

PTC relay 1: Sluk

PTC relay 2: Sluk

PTC relay 3: Sluk

Fragrance generator state: Sluk

A/C status: Ikke defineret

LIN communication: forbeholdt

Solar sensor element left: 850 W/m2

Solar sensor element right: 1530 W/m2

A/C compressor high voltage status: --

Hastighed for A/C-kompressor: --

DC bus current consumption (LSB): -- A

DC bus current consumption (MSB): -- A

PCB temperature: -- °C

High voltage measurement: -- V

Medium temperature 1 (outlet by default): -- °C

Electronic expansion valve current initialization status: --

Electronic expansion valve running status: --

A/C compressor safety default (include interlock): --

Over temperature indicator: --

Current sensor fault: --

Defect of heater legs indicator: --

Diagnostic configuration: --

Left outlet temperature: -- °C

Right outlet temperature: -- °C

Rear blower: -- V

Rear blower output (PWM duty): -- %

Ambient temperature (raw): -- °C