Bil, CHERY, OMODA C5, Driver seat heating unit row 1 (SHU1D)
Sæde moduler - Driver seat heating unit row 1 (SHU1D) - 0
Identifikation
System supplier ECU calibration data part number: 123456789@AB
System supplier ECU software part number: 123456789@AB
Application ID: 123456789@ABC
System supplier ECU calibration data version number: 123456789
Programming date: 31 32 33
Fingerprint 1 value: 31 32 33
Fingerprint 2 value: --
Logistics assembly part number: --
Logistics hardware part number: --
System supplier ECU hardware number: 123456789
System supplier ECU software version number: 123456789
Calibration parameter version number: 12345678
Repair shop code or tester serial number: --
Active diagnostic session: 31
Calibration data: --
Vehicle manufacturer logistic software part number: 123456789@AB
System name: 123456789@AB
Stel nr.: --
Fremstillings dato: 31 32 33 34
Hardware number: 12345
ECU serial number: --
System supplier: 123
Software nummer: 12345678
Spare part number: --
Boot software identification: --
Fejlkoder
Controls
Clear DTC
Levende Data
Left hall: Ikke defineret
Right hall: Ikke defineret
Seat adjustment - backrest: 12594
Backrest default position: --
Backrest maximum action time: --
Backrest maximum distance between soft and stall stop: --
Backrest minimum distance between soft and stall stop: --
Backrest total distance: 16706
Cushion position: 13108
Cushion maximum action time: --
Cushion maximum distance between soft and stall stop: --
Cushion total distance: 17152
Cushion minimum distance between soft and stall stop: --
Easyentry distance: --
Horizontal default position: --
Horizontal minimum distance between soft and stall stop: --
Horizontal maximum distance between soft and stall stop: --
Horizontal maximum action time: --
Vertical default position: --
Vertical maximum starting distance: --
Vertical minimum distance between soft and stall stop: --
Vertical maximum distance between soft and stall stop: --
Vertical maximum action time: --
Target temperature 1: 49
Target temperature 2: 54
Target temperature 3: 65
Maximum threshold temperature 1 for high temperature maintenance: 53
Maximum threshold temperature 2 for high temperature maintenance: 64
Maximum threshold temperature 3 for high temperature maintenance: --
Maximum temperature 1 value for rapid heating: 50
Maximum temperature 2 value for rapid heating: 55
Maximum temperature 3 value for rapid heating: 66
Hall sensor signal 1: Aktiv
Hall sensor signal 2: Ikke aktiv
Analog input: 31 32 33 34
Udgangs test
Controls
Seat heating
Seat heating indicator
Seat cushions back and forth
Seat ventilation
Seat ventilation indicator
Seat back angle