Bil, KIA, General, SPORTAGE (SL), 2014, G 2.0 MPI THETA II, SMART Key Module (SMK)

Keyless - SMART Key Module (SMK) - 0

Identifikation

Vehicle name: SL

Dele nummer: 95480-3U001

Part name: SMK

Fremstillings dato: 20100809

Softwareversion: 07 20

Product no. :: 0AM80301

Serie nummer: 0A 08 06 00 1A

Can DB ver.: 01 34

Hardware version nummer: 01

HMC/KMC hardware version: 01

HMC/KMC software version: 03

Fejlkoder

B1625: ECM reception error or ECM data error

Controls

Clear DTC

Levende Data

Start stop button 2: Tænd

ACC: Tænd

Ignition 1: Tænd

Gearshift P Position(AT)/Clutch(MT): Tænd

Driver door handle toggle button switch: --

Passenger door handle toggle button switch: --

Stop light switch: --

Start stop button 1: --

Trunk lid switch (Tail gate switch): --

FOB in switch: --

Ignition 2: --

Start relay feed back signal: --

Stop lamp fuse status: --

ESCL unlock signal: --

Battery voltage (ADC): 12.64 V

Motor Hastighed: 768 Omdr.

Køretøjs hastighed : 0 km/h

ESCL battery output: 0.00 V

ESCL ground output: 0.00 V

ACC relay voltage output: 12.32 V

IGN1 relay voltage output: 12.40 V

IGN2 relay voltage output: 12.32 V

Starter relay voltage output: 0.16 V

Battery voltage monitoring Input(by Load): 12.64 V

ESCL enable output: Sluk

ESCL battery output: Sluk

Immobilizer telltale: Sluk

ESCL ground output: Sluk

External buzzer: Sluk

Start stop button LED blue/green: Sluk

FOB holder illumination output: Sluk

ACC relay output: Tænd

Start stop button illumination GND output: Tænd

Ignition 1 relay output: Tænd

Start stop button illumination power output: Tænd

Ignition 2 relay output: Tænd

Start stop button LED amber: Sluk

Starter relay output: Sluk

IGN1 OFF output: Sluk

IGN2 OFF output: Sluk

Ignition 1 output circuit short to battery: Sluk

ACC output short circuit to Battery(Present): Sluk

Ignition 1 output circuit short to ground: Sluk

ACC output circuit short to ground(Present): Sluk

IGN1 input short circuit to Battery(Present): Sluk

ACC input short circuit to Battery(Present): Sluk

IGN1 input Open(Present): Sluk

ACC input Open(Present): Sluk

Starter output short circuit to Battery(Present): Sluk

Ignition 2 output circuit short to battery: Sluk

Starter output circuit short to ground(Present): Sluk

Ignition 2 output circuit short to ground: Sluk

Starter P/N SW short circuit to Battery(Present): Sluk

IGN2 input short circuit to Battery(Present): Sluk

IGN2 input Open(Present): Sluk

Button status: Lås op

Key n p1 is learnt: Tænd

Key n p2 is learnt: Tænd

SMK status: Learnt

Number of learnt FOB key: 2

ESCL failure factor: No factor

Udgangs test

Controls

Immobilizer telltale

External buzzer

ESCL Enable(ESCL only)

Start stop button LED amber

Start stop button LED blue/green

FOB holder illumination

Start Stop Button Illumination

ACC relay

IGN1 Relay

IGN2 Relay

Start Relay

Interior antenna 1

Interior antenna 2

Interior antenna 3

Bumper/tailgate antenna

Driver door handle antenna

Assist Door Handle Antenna

Muligheder

Controls

Interior antenna 1

Interior antenna 2

Interior antenna 3 (RV/Hatchback only)

Bumper/tailgate antenna

Driver door handle antenna

Passenger door handle antenna

Receiver communication line check

ESCL communication line check

ECM neutralization

SMK neutralization

ESCL neutralization

SMK status information

Fjernbetjenings nøgle status

ESCL status information

ESCL open status check

Current FOB key check

Smart key code saving