Bil, KIA, General, PICANTO (TA), 2019, L 1.0 LPGi KAPPA, SMART Key Module (SMK)

Keyless - SMART Key Module (SMK) - 0

Identifikation

Vehicle name: €

Dele nummer:

Part name:

Fremstillings dato:

Softwareversion: FF FF

Product no. ::

Serie nummer: FF FF FF FF FF

Can DB ver.: FF FF

Hardware version nummer: FF

Fejlkoder

B1978: ESCL failure

Controls

Clear DTC

Levende Data

Start stop button 2: Tænd

ACC: Tænd

Ignition 1: Tænd

Gearshift P Position(AT)/Clutch(MT): Tænd

Driver door handle toggle button switch: --

Passenger door handle toggle button switch: --

Stop light switch: --

Start stop button 1: --

Trunk lid switch (Tail gate switch): --

Ignition 2: --

Start relay feed back signal: --

Stop lamp fuse status: --

ESCL unlock signal: --

Battery voltage (ADC): 20.40 V

Køretøjs hastighed : 255 km/h

ESCL battery output: 20.40 V

ESCL ground output: 20.40 V

ACC relay voltage output: 20.40 V

IGN1 relay voltage output: 20.40 V

IGN2 relay voltage output: 20.40 V

Starter relay voltage output: 20.40 V

Battery voltage monitoring Input(by Load): 20.40 V

ESCL enable output: Tænd

ESCL battery output: Tænd

Immobilizer telltale: Tænd

ESCL ground output: Tænd

External buzzer: Tænd

Start stop button LED blue/green: Tænd

ACC relay output: Tænd

Start stop button illumination GND output: Tænd

Ignition 1 relay output: Tænd

Start stop button illumination power output: Tænd

Ignition 2 relay output: Tænd

Start stop button LED amber: Tænd

Starter relay output: Tænd

IGN1 OFF output: Tænd

IGN2 OFF output: Tænd

Ignition 1 output circuit short to battery: Tænd

ACC output short circuit to Battery(Present): Tænd

Ignition 1 output circuit short to ground: Tænd

ACC output circuit short to ground(Present): Tænd

IGN1 input short circuit to Battery(Present): Tænd

ACC input short circuit to Battery(Present): Tænd

IGN1 input Open(Present): Tænd

ACC input Open(Present): Tænd

Starter output short circuit to Battery(Present): Tænd

Ignition 2 output circuit short to battery: Tænd

Starter output circuit short to ground(Present): Tænd

Ignition 2 output circuit short to ground: Tænd

Starter P/N SW short circuit to Battery(Present): Tænd

IGN2 input short circuit to Battery(Present): Tænd

IGN2 input Open(Present): Tænd

Key n p3 is learnt: Sluk

Button status: -

Key n p1 is learnt: Sluk

Key n p2 is learnt: Sluk

Transponder status: Immo coil error

SMK status: Virgin

Number of learnt FOB key: 2

ESCL failure factor: --

Udgangs test

Controls

Start stop button LED amber

Start stop button LED blue/green

Start Stop Button Illumination

ACC relay

IGN1 Relay

IGN2 Relay

Start Relay

External buzzer

Immobilizer telltale

ESCL Enable(ESCL only)

Interior antenna 1

Interior antenna 2

Bumper/tailgate antenna

Left Door Handle Antenna

Right Door Handle Antenna

Muligheder

Controls

Interior antenna 1

Interior antenna 2

Bumper/tailgate antenna

Driver door handle antenna

Passenger door handle antenna

ESCL communication line check

ECM neutralization

SMK neutralization

ESCL neutralization

SMK status information

Fjernbetjenings nøgle status

ESCL status information

ESCL open status check

Current FOB key check

Smart key code saving