Bil, KIA, General, PICANTO (TA), 2016, G 1.0 MPI KAPPA, SMART Key Module (SMK)
Keyless - SMART Key Module (SMK) - 0
Identifikation
Vehicle name:
Dele nummer:
Part name:
Fremstillings dato:
Softwareversion: FF FF
Product no. ::
Serie nummer: FF FF FF FF FF
Can DB ver.: FF FF
Hardware version nummer: FF
Fejlkoder
B1978: ESCL failure
Controls
Clear DTC
Levende Data
Start stop button 2: Tænd
ACC: Tænd
Ignition 1: Tænd
Gearshift P Position(AT)/Clutch(MT): Tænd
Driver door handle toggle button switch: --
Passenger door handle toggle button switch: --
Stop light switch: --
Start stop button 1: --
Trunk lid switch (Tail gate switch): --
Ignition 2: --
Start relay feed back signal: --
Stop lamp fuse status: --
ESCL unlock signal: --
Battery voltage (ADC): 20.40 V
Køretøjs hastighed : 255 km/h
ESCL battery output: 20.40 V
ESCL ground output: 20.40 V
ACC relay voltage output: 20.40 V
IGN1 relay voltage output: 20.40 V
IGN2 relay voltage output: 20.40 V
Starter relay voltage output: 20.40 V
Battery voltage monitoring Input(by Load): 20.40 V
ESCL enable output: Tænd
ESCL battery output: Tænd
Immobilizer telltale: Tænd
ESCL ground output: Tænd
External buzzer: Tænd
Start stop button LED blue/green: Tænd
ACC relay output: Tænd
Start stop button illumination GND output: Tænd
Ignition 1 relay output: Tænd
Start stop button illumination power output: Tænd
Ignition 2 relay output: Tænd
Start stop button LED amber: Tænd
Starter relay output: Tænd
IGN1 OFF output: Tænd
IGN2 OFF output: Tænd
Ignition 1 output circuit short to battery: Tænd
ACC output short circuit to Battery(Present): Tænd
Ignition 1 output circuit short to ground: Tænd
ACC output circuit short to ground(Present): Tænd
IGN1 input short circuit to Battery(Present): Tænd
ACC input short circuit to Battery(Present): Tænd
IGN1 input Open(Present): Tænd
ACC input Open(Present): Tænd
Starter output short circuit to Battery(Present): Tænd
Ignition 2 output circuit short to battery: Tænd
Starter output circuit short to ground(Present): Tænd
Ignition 2 output circuit short to ground: Tænd
Starter P/N SW short circuit to Battery(Present): Tænd
IGN2 input short circuit to Battery(Present): Tænd
IGN2 input Open(Present): Tænd
Key n p3 is learnt: Sluk
Button status: -
Key n p1 is learnt: Sluk
Key n p2 is learnt: Sluk
Transponder status: Immo coil error
SMK status: Virgin
Number of learnt FOB key: 2
ESCL failure factor: --
Udgangs test
Controls
Start stop button LED amber
Start stop button LED blue/green
Start Stop Button Illumination
ACC relay
IGN1 Relay
IGN2 Relay
Start Relay
External buzzer
Immobilizer telltale
ESCL Enable(ESCL only)
Interior antenna 1
Interior antenna 2
Bumper/tailgate antenna
Left Door Handle Antenna
Right Door Handle Antenna
Muligheder
Controls
Interior antenna 1
Interior antenna 2
Bumper/tailgate antenna
Driver door handle antenna
Passenger door handle antenna
ESCL communication line check
ECM neutralization
SMK neutralization
ESCL neutralization
SMK status information
Fjernbetjenings nøgle status
ESCL status information
ESCL open status check
Current FOB key check
Smart key code saving