PKW, KIA, Korea, MORNING (TA), 2016, G 1.0 MPI KAPPA, SMART Key Module (SMK)

Diebstahl- warnanlage - SMART Key Module (SMK) - 0

Identifikation

Fahrzeugname: €

Ersatzteilnummer:

Ersatzteilname:

Herstellungsdatum:

Softwareversion: FF FF

Product no. ::

Seriennummer: FF FF FF FF FF

Can DB ver.: FF FF

Hardwareversion: FF

Fehlercode

B1602: CAN-Bus-Kommunikationsfehler

Controls

Fehlercode löschen

Ist-Werte

Start stop button 2: EIN

ACC: EIN

Zündung 1: EIN

Gearshift P Position(AT)/Clutch(MT): EIN

Driver door handle toggle button switch: EIN

Passenger door handle toggle button switch: EIN

Bremslichtschalter: EIN

Start stop button 1: EIN

Trunk lid switch (Tail gate switch): EIN

Zündung 2: EIN

Start relay feed back signal: EIN

Stop lamp fuse status: EIN

Batteriespannung (ADC): 20.40 V

Fahrgeschwindigkeit: 255 km/h

ACC relay voltage output: 20.40 V

IGN1 relay voltage output: 20.40 V

IGN2 relay voltage output: 20.40 V

Starter relay voltage output: 20.40 V

Battery voltage monitoring Input(by Load): 20.40 V

Anzeige Wegfahrsperre : EIN

External buzzer: EIN

Start stop button LED blue/green: EIN

ACC relay output: EIN

Start stop button illumination GND output: EIN

Ignition 1 relay output: EIN

Start stop button illumination power output: EIN

Ignition 2 relay output: EIN

Start stop button LED amber: EIN

Starter relay output: EIN

IGN1 OFF output: EIN

IGN2 OFF output: EIN

Ignition 1 output circuit short to battery: EIN

ACC output short circuit to Battery(Present): EIN

Ignition 1 output circuit short to ground: EIN

ACC output circuit short to ground(Present): EIN

IGN1 input short circuit to Battery(Present): EIN

ACC input short circuit to Battery(Present): EIN

IGN1 input Open(Present): EIN

ACC input Open(Present): EIN

Starter output short circuit to Battery(Present): EIN

Ignition 2 output circuit short to battery: EIN

Starter output circuit short to ground(Present): EIN

Ignition 2 output circuit short to ground: EIN

Starter P/N SW short circuit to Battery(Present): EIN

IGN2 input short circuit to Battery(Present): EIN

IGN2 input Open(Present): EIN

Key n p3 is learnt: AUS

Button status: -

Key n p1 is learnt: AUS

Key n p2 is learnt: AUS

Transponder status: Immo coil error

SMK status: Neu

Anzahl der angelernten Funktaster-Schlüssel: 2

Stellgliedtest

Controls

Start stop button LED amber

Start stop button LED blue/green

Start Stop Button Illumination

ACC relay

IGN1 Relay

IGN2 Relay

Start Relay

External buzzer

Anzeige Wegfahrsperre

Innenantenne 1

Innenantenne 2

Antenne Stoßstange/Heckklappe

Left Door Handle Antenna

Right Door Handle Antenna

Dienst­programme

Controls

Innenantenne 1

Innenantenne 2

Antenne Stoßstange/Heckklappe

Antenne Fahrertürgriff

Antenne Beifahrertürgriff

ECM Neutralisation

SMK Neutralisation

SMK Statusinformation

Status-Information Funktaster-Schlüssel

Überprüfung aktueller FOB Schlüssel

Speicherung Code für Smart Key