Bil, HYUNDAI, General, I20 (PB), 2013, G 1.2 MPI, Smart key code saving (without ESCL) (SMK)
Keyless - Smart key code saving (without ESCL) (SMK) - 0
Identifikation
Vehicle name:
Dele nummer:
Part name:
Fremstillings dato:
Softwareversion: FF FF
Product no. ::
Serie nummer: FF FF FF FF FF
Can DB Ver. :: FF FF
Hardware version nummer: FF
Fejlkoder
B1602: CAN-bus communication error
B1603: CAN-bus off
Controls
Clear DTC
Levende Data
Start stop button 2: Tænd
ACC: Tænd
Ignition 1: Tænd
Gearshift P Position(AT)/Clutch(MT): Tænd
Driver door handle toggle button switch: Tænd
Passenger door handle toggle button switch: Tænd
Stop light switch: Tænd
Start stop button 1: Tænd
Trunk lid switch (Tail gate switch): Tænd
Ignition 2: Tænd
Start relay feed back signal: Tænd
Stop lamp fuse status: Tænd
Battery voltage (ADC): 20.40 V
Motor Hastighed: 8160 Omdr.
Køretøjs hastighed : 255 km/h
ACC relay voltage output: 20.40 V
IGN1 relay voltage output: 20.40 V
IGN2 relay voltage output: 20.40 V
Starter relay voltage output: 20.40 V
Battery voltage monitoring Input(by Load): 20.40 V
Immobilizer telltale: Tænd
External buzzer: Tænd
Start stop button LED blue/green: Tænd
ACC relay output: Tænd
Start stop button illumination GND output: Tænd
Ignition 1 relay output: Tænd
Start stop button illumination power output: Tænd
Ignition 2 relay output: Tænd
Start stop button LED amber: Tænd
Starter relay output: Tænd
IGN1 OFF output: Tænd
IGN2 OFF output: Tænd
Ignition 1 output circuit short to battery: Tænd
ACC output short circuit to Battery(Present): Tænd
Ignition 1 output circuit short to ground: Tænd
ACC output circuit short to ground(Present): Tænd
IGN1 input short circuit to Battery(Present): Tænd
ACC input short circuit to Battery(Present): Tænd
IGN1 input Open(Present): Tænd
ACC input Open(Present): Tænd
Starter output short circuit to Battery(Present): Tænd
Ignition 2 output circuit short to battery: Tænd
Starter output circuit short to ground(Present): Tænd
Ignition 2 output circuit short to ground: Tænd
Starter P/N SW short circuit to Battery(Present): Tænd
IGN2 input short circuit to Battery(Present): Tænd
IGN2 input Open(Present): Tænd
Button status: --
Key n p1 is learnt: --
Key n p2 is learnt: --
Transponder status: --
SMK status: --
Number of learnt FOB key: 255
Udgangs test
Controls
Start stop button LED amber
Start stop button LED blue/green
Start Stop Button Illumination
ACC relay
IGN1 Relay
IGN2 Relay
Start Relay
External buzzer
Immobilizer telltale
Interior antenna 1
Interior antenna 2
Trunk antenna (Sedan only)
Bumper/tailgate antenna
Left Door Handle Antenna
Right Door Handle Antenna
Muligheder
Controls
Interior antenna 1
Interior antenna 2
Trunk antenna (Sedan only)
Bumper/tailgate antenna
Driver door handle antenna
Passenger door handle antenna
ECM neutralization
SMK neutralization
SMK status information
Fjernbetjenings nøgle status
Current FOB key check
Smart key code saving